Ross DM1E Скачать руководство пользователя страница 7

7  Commissioning and Operation

 CAUTION

Damage to health due to loud noise!

Levels above 70 dB(A) may lead to damage to health!

 

f

Always wear ear protectors when working on the product.

Before commissioning, the installation has to be carefully inspected by a quali-
 ed, trained professional.

 

f

Make sure that the technical data matches the operating criteria of the ma-
chine and/or the pneumatic system.

 

f

Always set the compressed air supply to a level that ensures that the mini-
mum operating pressure is adhered to (see section 8 „Technical Data“).

The reset valve (not available with DM1E) may only be actuated by a pulse 
(electrical, manual, or pneumatic) of max. 3 seconds and with solenoids a + b 
switched off..

For pneumatic resets, the reset pressure must be higher than or equal 
to the operating pressure!

 

f

Before valve assembly and before initial commissioning, always actuate 
the reset valve to switch the DM valve to its normal position.
In this switching position, the DM valve is ready to run.

7.1  Conducting a function test

Test

Result

1.  Solenoid “a” actuated

Valve is in lockout position, 
slight leakage at connection 3.

De-energize DM1E! Actuate reset for DM2E!

Valve ready to run again.

2.  Solenoid “b” actuated

Valve is in lockout position, 
slight leakage at connection 3.

De-energize DM1E! Actuate reset for DM2E!

Valve ready to run again.

3.  Solenoids “a” and “b” 

actuated within t < 0.1 s

Valve switches properly.

4.  Solenoids “a” and “b” 

actuated with t > 0.1 s

Valve switches to lockout position, 
slight leakage at connection 3.

5.  After fault, permanent signal at 

reset valve – solenoids “a” and “b” 
or only “a” or only “b” actuated

If the valve remains deactivated, 
slight leakage at connection 3.

De-energize DM1E! Actuate reset for DM2E!

Valve ready to run again.

If this function test provides deviating results, see section 4 „Service, 
Repair, and Maintenance“.

Each asynchronous movement of the piston elements > 0.1 s leads to the valve 
switching off. This could happen for a variety of reasons, such as:
•  Defective piston seals,
•  Main valve elements experiencing a switching delay due to dirt or resinous 

oil,

• Insuf cient electrical signals to valve solenoids; suitable voltage not availa-

ble,

•  Receipt of signals at solenoids not synchronous,
•  Pilot valves experiencing a switching delay due to damaged components, 

dirt, or resinous oil,

•  excessive water build-up in the valve.

8  

Technical Data

Design: 

Two redundant 3/2 directional main valve elements in seat-valve de-

sign, normally closed. Pneumatically operated. Combined spring and air reset.

Actuation:

 Solenoid-operated pilot control.

Medium:

 Compressed air (neutral gases),  ltered in acc. with ISO 8573-1 

(class 7 / 40 m, recommended: class 6 / 5 m), oiled or oil-free (mineral oils 
according to DIN 51519/ISO-VG, viscosity class 32).

Pressure range: 

2 to 8 bar. 

Ambient temperature: 

-10°C to 50°C. 

Medi-

um temperature:

 4°C to 80°C.

For temperatures below 4°C, the compressed air must be dried according 
to ISO 8573-3, class 7.

Shock test

 (based on DIN EN 60068-2-27):

•  Acceleration: 30 g.
•  Shock duration: 18 ms.
•  Shock waveform: Half-sine.
•  Vibration test (vibration based on DIN EN 60068-2-6):
•  Frequency: 10 to 55 Hz.
•  Amplitude: 0.35 mm ± 0.05 mm.

Min. switching frequency:

 1x per month, to ensure proper function

Max. switching frequency:

 30 Hz measured without volume. The switching 

frequency decreases depending on the volume to be controlled.

Mounting orientation:

 Any, preferably vertical.

Monitoring:

 Dynamic, cyclic, internal – with any change in switching state and 

in any switching state.

Solenoids:

 Version as per VDE 0580. Designed for continuous operation

Electrical connection according to DIN EN 175301-803 form A (previously 
DIN 43650, form A). Protection class according to DIN 400 50 IP 65.

Status indicator unit optional (pressure switch):

 NO/NC contacts – 

5 A 250 VAC, or 5 A 30 VDC.

Standard voltages:

 24 V DC, 110 V 50-60 Hz, 220/230 V 50-60 Hz, 

other voltages on request.

Voltage tolerance:

 ±10%.

B

10

 value according to DIN 13849-1 and -2:

 Service life parameter measured 

according to ROSS Engineering Standard, Laboratory Test Procedures Sec-
tion 8: B

10

 = 10 million switching cycles, B

10d

 = 20 million switching cycles

Sound pressure level [dB(A)]: 

DM1E

®

 = 86 / DM2E

®

 = 88 / DM2C

®

 = 91, 

max. impulse sound pressure level at the loudest measuring point when ex-
hausting the valve with a corresponding D5500 silencer

Power consumption:

Pilot valve/
reset valve

24 V DC

110 V AC

220/230 V AC

[W]

Pull-in [VA]

Hold [VA]

Pull-in [VA]

Hold [VA]

Pilot valve 
(sizes 2, 4, 12, 30)

5.8 W

15.8

12.8 

14.4 

10.4 

Pilot valve (size 8)

15 W

35.4 

22.9 

35.7 

23.2 W

Reset valves

5.8 W

15.8 

12.8 

14.4 

10.4

9  

Order Key (Example)

PRODUCT

ERROR DISPLAY UNIT

 .................................... Yes

X

 .....................................  No

ERROR DISPLAY UNIT

 .........................

Pneumatic

 ..............................

Electric

 ..........................

Automatic

After switching the com-
pressed air on again

VOLTAGE

A

 .............................  24  VDC

B

 ............................ 110 VAC

C

 ..................... 220/230 VAC

D

 ..............................12 VDC

THREAD

BSP

 ............................

D

NPT

 ............................

N

Without base plate

 ......

X

CHANGE STATUS

SIZE
2  .................................  

2

4  .................................  

4

8  .................................  

5

12  ...............................  

6

30  ...............................  

8

DM1E / DM2E / DM2C

D

A

2

0

A

2

1

BASE PLATE CONNECTION

G 1/4 inlet – G 1/4 outlet  ............................  

0 (1340 / 2420)

G 3/8 inlet – G 3/8 outlet  ............................  

1 (1950 / 2420)

G 1/2 inlet – G 1/2 outlet  ............................  

2 (2990 / 2990)

G 3/4 inlet – G 3/4 outlet  ............................  

4 (4390 / 4390)

G 1 inlet – G 1 outlet  ..................................  

5 (4400 / 4400)

G 1 inlet – G 1 outlet  ..................................  

6 (8500 / 8500)

G 1 1/2 inlet – G 2 outlet  ........................  

8 (21900 / 21900)

N/A (without base plate) ....................................................

X

(Flow rate values Qn at 6 

EDU¨S

 = 1 bar [l/min] Connections: 1-2 / 2-3)

  DM1E, DM2E, DM2C | English 

4

Содержание DM1E

Страница 1: ...umatisk tvillingmagnetventil DM1E DM2E DM2C RE 02 10 2014 DE EN FR IT ES SV U S Patent Nr 6804256 6840259 weitere Patentanmeldungen weltweit U S patent no 6804256 6840259 further patents led worldwide...

Страница 2: ...regler Pressure regulator R gulateur de pression Riduttore di pressione Regulador de presi n Tryckregulator 3 Manometer Pressure gauge Manom tre Manometro Man metro Manometer 4 lvernebler Oil vaporize...

Страница 3: ...Konformit tserkl rung Declaration of conformity D claration de conformit Dichiarazione di conformit Declaraci n de conformidad Konformitetsf rklaring 5...

Страница 4: ...mory Fehlerspeicherung und Reset Funktion Zur cksetzen Das Produkt wurde nach den grundlegenden und bew hrten Sicherheitsprinzi pien der ISO 13849 1 und 2 entwickelt und gefertigt 5 1 2 Ausf lle aufgr...

Страница 5: ...rtung Jede asynchrone Bewegung der Kolbenelemente 0 1 s f hrt zu Ventilabschal tungen Diese k nnen verschiedene Ursachen haben wie zum Beispiel defekte Kolbendichtungen verz gerte Schaltung der Hauptv...

Страница 6: ...permissible values for vibration and impact loading Observe the temperature range Observe the compressed air quality as speci ed in the technical data Observe the permissible operating pressure 5 2 F...

Страница 7: ...n Solenoid operated pilot control Medium Compressed air neutral gases ltered in acc with ISO 8573 1 class 7 40 m recommended class 6 5 m oiled or oil free mineral oils according to DIN 51519 ISO VG vi...

Страница 8: ...namique De plus les s ries DM2E DM2C sont dot es d une fonction de m morisation enregistrement des erreurs et de r initialisati on remise z ro Le produit a t d velopp et fabriqu conform ment aux princ...

Страница 9: ...aible fuite au raccordement 3 En cas de mod le DM1E mettre hors tension En cas de mod le DM2E actionner le rappel Vanne nouveau op rationnelle Si ce test de fonctionnement se conclut par d autres r su...

Страница 10: ...ze nell impiego della tecnica di comando elettrica e pneumatica 3 Fornitura Sono compresi nella fornitura Valvola DM Istruzioni per l uso 2 tappi per il secondo collegamento 1 2 vedere anche capitolo...

Страница 11: ...formato Il prodotto pu essere utilizzato soltanto nel rispetto di quanto indicato nel capitolo Uso a norma delle presenti istruzioni per l uso I cavi i collega menti e l azionamento elettrico delle va...

Страница 12: ...O PLQ SDUDPHWUL FROOHJDPHQWR Espa ol 1 Acerca de esta documentaci n Estas instrucciones contienen informaci n importante para montar y poner en funcionamiento el producto de un modo seguro y apropiad...

Страница 13: ...r sticas constructivas impiden en gran medida que se produzca el embotamiento f Utilice las v lvulas DM nicamente con el silenciador correctamente monta do f Aseg rese de que no se limite la capacidad...

Страница 14: ...ertical Supervisi n din mica c clica interna con cada cambio de estado de conmu taci n y en cada estado de conmutaci n Imanes versi n seg n VDE 0580 Dise ados para servicio continuo Conexi n el ctrica...

Страница 15: ...s kerhetsprinciper enligt ISO 13849 1 och 2 5 1 2 Felfunktion p grund av gemensam orsak Common Cause Failure CCF Fel p grund av gemensam orsak inneb r bortfall av s kerhetsfunktionen efter som i detta...

Страница 16: ...te magneterna synkront f rdr jd koppling av pilotventiler p grund av defekta komponenter neds mutsning eller f rh rdnad olja f r mycket vatten i ventilen 8 Tekniska data Konstruktion Tv redundanta 3 2...

Страница 17: ......

Страница 18: ...Fon 49 0 6103 7597 0 Fax 49 0 6103 74694 info rosseuropa com www rosseuropa com Originalfassung in Deutsch Original version in German Version originale en allemand Testo originale in lingua tedesca R...

Отзывы: