b. A clean dry source compressed air rated at 80-100psig @ 10cfm will need to be installed to the inlet of the
manual 3-way air control valve located on the top of the air/oil hydraulic reservoir. Hard piping the
compressed air line is recommended. Use the largest hose or pipe permitted. A small air line will cause an
extended time frame to pressurize the reservoir and time to raise the Mixer.

c. After filling the air/oil hydraulic reservoir and installing the compressed air line, the hydraulic cylinder will
need to be bled of all air by using the air bleed valve located on the upper cylinder wall, near the upper flange
of the cylinder. Apply compressed air to the cylinder by moving the 3-way control valve to the "pressure"
location. When the reservoir is pressurized, depress the hand valve to allow oil to flow into the cylinder.
Open the bleed valve on the top/side of the cylinder and allow the air to bleed out of the cylinder. All of the
air is bled when the oil comes out of the bleed valve in a clear stream without any air bubbles.

5. 

Shaft Seals.

a. As standard, the CDA Agitator Shafts are sealed with a Dry Running Double Flexi-Lip Seal. This Seal is
installed from below (underside of) the Vacuum Cover and requires no adjustment, lubrication or
maintenance. Keep the area around the seal clean and free of dirt/debris to protect the seal and provide a long
life for the seal.

b. As an option, the Agitator Shafts  may be sealed at the Vacuum Cover with single mechanical seals. These
mechanical seals and the lower shaft bearings are lubricated with oil. 

NEVER ALLOW THESE SEALS AND

BEARINGS TO RUN DRY.

  Check the oil level at the oil gauge sight on the side of the bearing housing/tower and

add oil as necessary to keep this sight gauge full at the center line. Use any good quality multigrade automotive oil
suitable for 250 to 300 degrees F. The upper shaft bearing is lubricated via grease and a grease fitting located
adjacent to the upper bearing.

6. Shaft Bearings.

 For all CDA mixers with Flexi-Lip Shaft Seals installed or  “Atmospheric” designs, the upper and

lower shaft bearings are lubricated via grease and the grease fitting located adjacent to the upper and lower bearings.
A breather is located between the bearings to allow heated air to escape.

7. Motor Bearings.

  These bearings have been greased at the factory and should be greased every 500 hours

minimum with a premium high temperature synthetic bearing grease if a grease fitting is installed on the motor. Smaller
HP motors will not have grease fittings and will have greased for life sealed bearings.

F. MIX CAN.

1. Before starting the mixing operation the mix can must be securely attached to the mixer can lock and
leveled to the vacuum cover/hood.

2. The can is positioned and held in place by two locking pins located at the back of the can.

G. THERMOCOUPLE, THERMOWELL.

The Thermocouple is located in the Vacuum Cover and/or in the sidewall of the Mix Can. Connect the
Thermocouple to the Control Panel as shown in the electrical wiring schematics. The typical Thermocouple is
a type "J". The Thermocouple wire must be matched with the type of Thermocouple.

H. GROUNDING CABLES.

Grounding cables are recommended to be installed between the Mixer and an earthen ground to dissipate any
potential static charges.  Additional grounding cables should be attached from the Mixer to the Mix Can and
other associated/attached equipment.

Содержание CDA-10

Страница 1: ...N COMPANY 1 CHARLESROSS SONCOMPANY CHARLES ROSS SON COMPANY 710 OLD WILLETS PATH HAUPPAUGE NY11788 PHONE 631 234 0500 FAX 631 234 0691 www mixers com CDA DUALSHAFTMIXER CDA 10 INSTALLATION MAINTENANCE...

Страница 2: ...UPLE THERMOWELL 9 H GROUNDING CABLES 9 OPERATION 10 A HYDRAULIC LIFT 10 B MIX CAN 10 C VARIABLE SPEED CONTROL 10 D MIXING 10 E VACUUM MIXING 11 MAINTENANCE 12 A AGITATOR SHAFT SEALS VACUUM RATED MIXER...

Страница 3: ...fety controls or other safety devices provided with the equipment must be in place and operational prior to operation of the equipment All rotating and or moving parts must be guarded during operation...

Страница 4: ...ve or the factory immediately E Mail Fax or Mail a copy of the inspection report and the delivery receipt indicating the problem areas at the time of delivery to sales mixers com Charles Ross Company...

Страница 5: ...Electrical Controls All electrical control panels are built to meet the National Electrical Code at the time of manufacture and are provided with disconnects that shut off power to the control circui...

Страница 6: ...d orreconditioningtherentedunit thecustomermust include the MSD sheet s of the material s that have been mixed in the rented unit The MSD sheet s are to be returnedwiththe rentedunit IftheMSDsheet s i...

Страница 7: ...e hydraulic lift cylinder in two directions at 90 degrees to each other front 0 degrees and side 90 degrees of the hydraulic lift cylinder This should provide a relatively vertically leveled installat...

Страница 8: ...ck the rotation of the shaft by jogging the drive motor Correct shaft rotation will be clock wise If the direction is reversed Lockout all power to the controls and reverse the connection of any two o...

Страница 9: ...ith oil NEVERALLOWTHESE SEALSAND BEARINGSTO RUN DRY Check the oil level at the oil gauge sight on the side of the bearing housing tower and add oilasnecessarytokeepthissight gaugefullatthecenterline U...

Страница 10: ...e Hydraulic Cylinder or on Base Extensions which are at the floor level Appropriate grounding cables should also be attached to the Mix Can C VARIABLE SPEED CONTROL 1 The speed of the agitators can be...

Страница 11: ...ncrease the evaporation of other volatiles such as solvents or wetting agents The reaction of each formula to vacuum is different and should be closely monitored during trial runs The horse power requ...

Страница 12: ...the shaft surface to its original 240 grit finish This is done by using 240 grit sand paper and then finish using a White Scotch Brite Hand Pad 7445 The shaft surface should appear as new with all scr...

Страница 13: ...Dry Running Flexi Lip Sealsand an ATMOSPHERIC RATED MIXER withoutseals are lubricated by grease and should be greased regularly or at least every 500 hours If a bearing makes anunusual noise orruns un...

Страница 14: ...per needs to be replaced 1 Pulloutthe oldwiperand thoroughly clean thegroove 2 Gentlytap the new wiperintothe groove witha fiber hammer alap jointwillresult 3 Pull out both ends of the joint fit the e...

Страница 15: ...isnotimportant Also refertotheVendorLiteratureformorespecific information 1 Reducer SyntheticAGMAlubricant 7EPor 8EP ISO ASTM viscosity grade 460 680 2 Bearings Anyhightemperature solvent resistant sy...

Страница 16: ...Valve 3 way 1 19 Hydraulic Control Valve Hand 1 20 Exhaust Muffler 1 21 Hydraulic Cylinder 5 Dia x 20 Stroke 42 OAH 1 22 Wiper Hydraulic Cylinder 1 23 Packing Gland Hydraulic Cylinder 1 24 Packing Ch...

Страница 17: ...Cap 1 58 Mechanical Seal Disperser Single Rotary Complete w 58a 1 58a Mechanical Seal Disperser Single Stationary Complete w 58 1 58b Lip Seal Teflon Option 1 59 Snap Ring Internal Disperser Shaft Lo...

Страница 18: ...2017 CHARLES ROSS SON COMPANY 18 SIDE VIEW CDA 10...

Страница 19: ...2017 CHARLES ROSS SON COMPANY 19 VACUUM COVER BEARING HOUSING VIEW CDA 10...

Страница 20: ...2017 CHARLES ROSS SON COMPANY 20 HSD BLADE VIEW CDA 10...

Страница 21: ...2017 CHARLES ROSS SON COMPANY 21 MIX CAN VIEW CDA 10...

Страница 22: ...2017 CHARLES ROSS SON COMPANY 22 THERMOCOUPLE ASSEMBLY LOW PROFILE 1 8 FLUSH MOUNT...

Страница 23: ...2017 CHARLES ROSS SON COMPANY 23 APPENDIX VENDOR PRODUCT INFORMATION...

Отзывы: