Ross CARBONITE GVG10 Скачать руководство пользователя страница 6

Notes

Bytes

ME / Keyer

Name

0x0C

Keyer/ME

Key Auto

0x0D

Keyer/ME

Key Cut

0x0E

ME

Wipe (transition)

0x0F

ME

Dissolve (transition)

Trying to turn off results in a protocol error.

0x10-0x19

ME

Preset Bus 0-9

Trying to turn off results in a protocol error.

0x1A

ME

Preset Bus On-Air

Always on; trying to turn off results in a

protocol error.

0x1B

ME

Aspect On

Always on; trying to turn off results in a

protocol error.

0x1C

ME

Positioner On

0x1D

ME

Reverse Wipe

Always true; we don't have DSKs – all our

keyers show on preview. Trying to turn off

results in a protocol error.

0x1E

Keyer

DSK Preview

0x1F

--

Fade to Black

Trying to turn off results in a protocol error.

0x20-0x29

Keyer/ME

Key Bus 0-9

Trying to turn off results in a protocol error.

0x2A

Keyer

Key Bus On-Air

Always true; trying to turn off results in a

protocol error.

0x2F

Keyer

Key Video Fill

Trying to turn off results in a protocol error.

0x30-0x39

ME

Wipe Type

DSKs; Trying to turn off results in a protocol

error.

0x40

Keyer/ME

Key Invert

DSKs; Trying to turn off results in a protocol

error.

0x41

Keyer

Key Mask

DSKs; Trying to turn off results in a protocol

error.

0x42

Keyer

Key AutoKey

DSKs; Trying to turn off results in a protocol

error.

0x43

Keyer

Key SelfKey

Trying to turn off results in a protocol error.

0x44

Keyer

Key Invert

Trying to turn off results in a protocol error.

0x45

Keyer

Key Mask

Toggles between memory mode and pattern

mode (are we changing patterns, or saving /

loading memories?).

0x47

--

Memory Mode Toggle

Trying to turn off results in a protocol error.

0x48

--

Next Trans is Background

Trying to turn off results in a protocol error.

0x49

--

Next Trans is Key 1

Trying to turn off results in a protocol error.

0x4A

ME

Cut

Trying to turn off results in a protocol error.

0x4C

Keyer/ME

Key Self Key

Trying to turn off results in a protocol error.

0x4D

Keyer/ME

Key Auto Key

6

Содержание CARBONITE GVG10

Страница 1: ...a serial connection to the switcher editor port Refer to the GV Grass Valley GVG100 setup sheet for information on connecting to an editor over a serial connection 2 At the gvg100 prompt enter the co...

Страница 2: ...f 1 means keyer 1 and effects address of 0 means keyer 2 Using this interpretation only keyers 1 and 2 of ME 1 are accessible Only ME 1 is accessible The table of supported GVG100 commands shows wheth...

Страница 3: ...d 157 ME 2 Program 160 ME 2 Preview 161 ME 2 Clean Feed 162 MiniME 1 210 MiniME 2 211 MiniME 3 212 MiniME 4 213 Table 3 CrossOver 12 Video Source Mapping Source Map To Black 0 Input BNC 1 8 1 8 Matte...

Страница 4: ...rite ME Program Bus An invalid xpt request returns a protocol error xpt C2 3 ME Write ME Preset Bus An invalid xpt request returns a protocol error xpt C3 C4 3 Keyer Write Keyer Bus control 45 3 Read...

Страница 5: ...is unused D0 F2 3 All Stop 0 78 3 Read Lamp Status Included for GVG100 spec completeness only F8 13 Write Lamp Status button FB 3 Any Write Button Press Table 6 Transition Rates Notes Bit Data Byte 0...

Страница 6: ...x2F Keyer Key Video Fill Trying to turn off results in a protocol error 0x30 0x39 ME Wipe Type DSKs Trying to turn off results in a protocol error 0x40 Keyer ME Key Invert DSKs Trying to turn off resu...

Страница 7: ...tton press has no effect 0x1B ME Aspect On Always on button press has no effect 0x1C ME Positioner On Doubles as memory store recall toggle when in memory mode 0x1D ME Reverse Wipe Always true we don...

Страница 8: ...Notes Bytes ME Keyer Name 0x4C Keyer Key Self Key 0x4D Keyer Key Auto Key 0x4E Keyer Key Chroma Key Editor control is always enabled 0x4F Editor Enable 8...