injectGVG100command("0501CC501405")
— select BKGD and keys 2 and 3 for the Next Trans of ME 2,
with a rate of 45.
•
injectGVG100command("0300FB1F")
— perform fade to black.
Supported GVG100 Commands
The switcher supports a number of GVG100 commands. The exact commands and how the switcher reacts to
the commands is outlined in the following tables.
Keep the following in mind when controlling the switcher via GVG100 commands:
• When performing a memory store or recall, the bus is set using the effects address, where 00 is all buses,
and specific buses are set using the effects address as a bitfield. For example an effects address of 02 (0000
0010) is ME 2, and 13 (0001 0011) is MEs 1, 2 and MiniME
™
3.
• When using Legacy mode, the effects address of 1 means keyer 1 and effects address of 0 means keyer 2.
Using this interpretation, only keyers 1 and 2 of ME 1 are accessible. Only ME 1 is accessible.
• The table of supported GVG100 commands shows whether the command uses the ME bits, the ME and keyer
bits, or neither. This only applies in Ross mode.
Table 1: Carbonite Effects Addresses
Bits for Memory Commands
Bits for Non-Memory Commands (Hex)
Bus
0000 0001
0000 0000 (0x00)
ME 1
0000 0010
0000 0001 (0x01)
ME 2
0000 0100
0000 0010 (0x02)
MiniME
™
1
0000 1000
0000 0011 (0x03)
MiniME
™
2
0001 0000
0000 0100 (0x04)
MiniME
™
3
0010 0000
0000 0101 (0x05)
MiniME
™
4
0100 0000
0000 0110 (0x06)
MultiScreen 1
1000 0000
0000 0111 (0x07)
MultiScreen 2
--
0000 0000 (0x00)
Key 1
--
0001 0000 (0x10)
Key 2
--
0010 0000 (0x20)
Key 3
--
0011 0000 (0x30)
Key 4
--
1000 0000 (0x80)
Aux 1
--
1000 0001 (0x81)
Aux 2
--
1000 0010 (0x82)
Aux 3
--
1000 0011 (0x83)
Aux 4
--
1000 0100 (0x84)
Aux 5
--
1000 0101 (0x85)
Aux 6
--
1000 0110 (0x86)
Aux 7
--
1000 0111 (0x87)
Aux 8
2