Ross CARBONITE GVG10 Скачать руководство пользователя страница 2

injectGVG100command("0501CC501405")

— select BKGD and keys 2 and 3 for the Next Trans of ME 2,

with a rate of 45.

injectGVG100command("0300FB1F")

— perform fade to black.

Supported GVG100 Commands

The switcher supports a number of GVG100 commands. The exact commands and how the switcher reacts to

the commands is outlined in the following tables.
Keep the following in mind when controlling the switcher via GVG100 commands:
• When performing a memory store or recall, the bus is set using the effects address, where 00 is all buses,

and specific buses are set using the effects address as a bitfield. For example an effects address of 02 (0000

0010) is ME 2, and 13 (0001 0011) is MEs 1, 2 and MiniME

3.

• When using Legacy mode, the effects address of 1 means keyer 1 and effects address of 0 means keyer 2.

Using this interpretation, only keyers 1 and 2 of ME 1 are accessible. Only ME 1 is accessible.

• The table of supported GVG100 commands shows whether the command uses the ME bits, the ME and keyer

bits, or neither. This only applies in Ross mode.

Table 1: Carbonite Effects Addresses

Bits for Memory Commands

Bits for Non-Memory Commands (Hex)

Bus

0000 0001

0000 0000 (0x00)

ME 1

0000 0010

0000 0001 (0x01)

ME 2

0000 0100

0000 0010 (0x02)

MiniME

1

0000 1000

0000 0011 (0x03)

MiniME

2

0001 0000

0000 0100 (0x04)

MiniME

3

0010 0000

0000 0101 (0x05)

MiniME

4

0100 0000

0000 0110 (0x06)

MultiScreen 1

1000 0000

0000 0111 (0x07)

MultiScreen 2

--

0000 0000 (0x00)

Key 1

--

0001 0000 (0x10)

Key 2

--

0010 0000 (0x20)

Key 3

--

0011 0000 (0x30)

Key 4

--

1000 0000 (0x80)

Aux 1

--

1000 0001 (0x81)

Aux 2

--

1000 0010 (0x82)

Aux 3

--

1000 0011 (0x83)

Aux 4

--

1000 0100 (0x84)

Aux 5

--

1000 0101 (0x85)

Aux 6

--

1000 0110 (0x86)

Aux 7

--

1000 0111 (0x87)

Aux 8

2

Содержание CARBONITE GVG10

Страница 1: ...a serial connection to the switcher editor port Refer to the GV Grass Valley GVG100 setup sheet for information on connecting to an editor over a serial connection 2 At the gvg100 prompt enter the co...

Страница 2: ...f 1 means keyer 1 and effects address of 0 means keyer 2 Using this interpretation only keyers 1 and 2 of ME 1 are accessible Only ME 1 is accessible The table of supported GVG100 commands shows wheth...

Страница 3: ...d 157 ME 2 Program 160 ME 2 Preview 161 ME 2 Clean Feed 162 MiniME 1 210 MiniME 2 211 MiniME 3 212 MiniME 4 213 Table 3 CrossOver 12 Video Source Mapping Source Map To Black 0 Input BNC 1 8 1 8 Matte...

Страница 4: ...rite ME Program Bus An invalid xpt request returns a protocol error xpt C2 3 ME Write ME Preset Bus An invalid xpt request returns a protocol error xpt C3 C4 3 Keyer Write Keyer Bus control 45 3 Read...

Страница 5: ...is unused D0 F2 3 All Stop 0 78 3 Read Lamp Status Included for GVG100 spec completeness only F8 13 Write Lamp Status button FB 3 Any Write Button Press Table 6 Transition Rates Notes Bit Data Byte 0...

Страница 6: ...x2F Keyer Key Video Fill Trying to turn off results in a protocol error 0x30 0x39 ME Wipe Type DSKs Trying to turn off results in a protocol error 0x40 Keyer ME Key Invert DSKs Trying to turn off resu...

Страница 7: ...tton press has no effect 0x1B ME Aspect On Always on button press has no effect 0x1C ME Positioner On Doubles as memory store recall toggle when in memory mode 0x1D ME Reverse Wipe Always true we don...

Страница 8: ...Notes Bytes ME Keyer Name 0x4C Keyer Key Self Key 0x4D Keyer Key Auto Key 0x4E Keyer Key Chroma Key Editor control is always enabled 0x4F Editor Enable 8...

Отзывы: