6. Adjust the height of the inside chimney to the position of the inside chimney bracket
and fix on it by screws, after adjusting the position, fix the body with safety screws.
Note: The two safety vents are positioned on the back housing, with diameter of
6mm.See pic 6 & 7.
Installation of T-shaped plastic outlet(optional)
1. As shown in pic 1,install the mounting bracket on the T-shaped plastic outlet with 4pcs
ST3*12mm screws.Then place the adjusted pipe to both sides of the outlet.
Adjust to
the required distance of adjustment pipe,make sure the left and right sides are
symmetrical,and fix it well with 2 pcs ST3*12mm screws.
2. See pic 2,2 pcs ST4*8mm screws will be used to fix the T-shaped plastic outlet to the
inside chimney bracket.
3. See pic 3,fix the inside chimney bracket and T-shaped plastic outlet on the wall with
ST4*30mm screws and wall plugs.
4. See pic 4 & pic 5,use 2 pcs ST4*8mm screws to fix the inside chimney to the inside
chimney bracket.