IMPORTANT WARNINGS
Electrical Connection and Security
1.
Your cooker is adjusted in compliance with 220-240V, 50/60Hz for
mono phase or 220-240V / 380-415V, 50/60Hz for three phase and 16
or 32 Ampere electric supply. If the mains is different from these values,
contact your authorized service.
2.
Electrical connection of the oven should only be made by the sockets
with earth system installed in compliance with the regulations. If there
is no proper socket with earth system in the place where the oven will be
installed, immediately contact a qualified electrician. Manufacturer shall
never be responsible from the damages that will arise because of the
sockets connected to the appliance with no earth system.
3.
Electrical cable should not touch the hot parts of the appliance.
4.
For disconnection from the supply mains having a contact separation
in all poles that provide full disconnection, must be incorporated in fixed
wiring in according with the wiring rules.
Gas Connection and Security
1.
Before your appliance is connected to the gas supply, ensure that
the gas category and pressure specifications shown in the data plate cor
-
responds with your gas supply. If necessary call authorized service for
adjusting to gas category.
2.
This appliance shall be installed in accordance with the regulations
in force and only used in a well ventilated space. Read the instructions
before installing or using this appliance. In the interest of safety this
appliances must be installed and / or serviced by a competent person as
stated in the gas safety regulations current editions.
3.
The appliance must not be installed in a room without a window or
other controllable opening. If is installed in a room without a door which
opens directly to the outside, a permanent opening is required. The air
circulation should be 2 m3/h per kW of burners.
4.
The gas connection should be performed from the right or left. For
this reason, change the hose nozzle, plug and the seals.
5.
Please use flexible hose for gas connection.
6.
If you make a connection with a flexible metal hose, locate a seal
between the main gas pipes.
7.
The inner diameter of the flexible hose, which the butane hose nozzle
is connected, should be 6mm for the house-type gas tubes. The inner
GB