9
diameter of the flexible hose, which the natural hose nozzle is connect
-
ed, should be 15mm.The hose should tightly be fitted to the hose nozzle
by squeezing with a clamp. The hose should be replaced before its last
expiry date.
8.
Caution! Make the oven connection to the gas inlet valve, the hose
length must be short and be sure that there is no leakage. The flexible
hose used should not be longer than 125 cm for safety.
9.
RE-INSPECT THE GAS CONNECTION.
10.
When placing your oven to its location, ensure that it is at the coun-
ter level. Bring it to the counter level by adjusting the feet if necessary.
DO NOT MAKE GAS HOSE and ELECTRICAL CABLE OF YOUR OVEN GO THROUGH
THE HEATED AREAS, ESPECIALLY THROUGH THE REAR SIDE OF THE OVEN. DO
NOT MOVE GAS CONNECTED OVEN. SINCE THE FORCING SHALL LOOSEN THE
HOSE, GAS LEAKAGE MAY OCCUR.
ELECTRICAL WIRING SCHEME
220-240V~50/60Hz
220-240V~50/60Hz
400V 3N~50/60Hz
400V 2N~50/60Hz
Earth
Terre
Erdung
Earth
Terre
Erdung
Earth
Terre
Erdung
Earth
Terre
Erdung
L3
L2
L1
L2
L1
L1
Live
Phase
Neutral
Neutre
Neutral
Neutre
Neutral
Neutre
FUSE SWITCH (25A/40A)
JUNCTION BOX
3x4mm²
3x4mm²
610mm
H05 VV-F 3G 4mm² H05 VV-F 5G 1.5mm² H05 VV-F 4G 1.5mm² H05 VV-F 3G 1.5mm²
CONSUMER UNI
T
Neutral
Neutre
GB