Page - 66 -
© 2014
SLF 2250/4000
Hydromatic Stinger
bar
ATTENTION !
To prevent damage of the vehicles roof installations, always use
the AUTO STOW function to return the boom to the transport
position.
CAUTION !
Sight contact with the turret is absolutely essential!
Never point the discharge jet at anybody.
DANGER OF INJURY TO PERSONNEL!
Stinger and Stinger Turret Operation
Boom turret - operation with water
- Operate the pump as mentioned in the
◊
"Tank Suction Operation" or
◊
"Drafting Operation from Open Water Source" or
◊
"Hydrant / Supply Operation" pump panel operation chapter.
- Prepare the boom for operation:
◊
Move the boom out of parking position and bring it to the
attack position - keep free space for turret pipe - please refer
to the "Boom Operation" chapter.
- Move the turret to desired position.
- Open turret discharge valve:
◊
Tilt and hold switch (S50) to the "ON" position as long as
water discharge is desired.
◊
OR Tilt switch (50) to the "HFO" position for permanent
discharge .
- The required discharge pressure and throwing range is control-
led via pump pressure governor or manually by using switch
(S9_) on the pump control panel or switch on the remote control.
- If required reduce to half discharge rate by using switch (S48).
- During operation the discharge jet is infinitely variable from
full- to spray-jet by turning joystick (S489).
Temporary stopping of turret operation:
◊
Close turret discharge valve.
Stopping of turret operation:
◊
Reduce the engine speed/pump pressure.
◊
Close turret discharge valve.
◊
Move the boom to transport position.
S9-
S9+
S9
S50
S489