Page - 50 -
© 2014
SLF 2250/4000
Hydromatic Stinger
Engaging the Water Pump
Engaging the Water Pump
Engaging the water pump from the driver´s cabin
- Stop the vehicle.
- Shift gear into neutral.
- Apply parking brake.
◊
Uncontrolled movement of vehicle could cause personnel
injury.
- Let engine idle - release accelerator pedal.- Engage the P.T.O.
(Power Take Off I) for the water pump:
◊
Press P.T.O.-switch (S2).
◊
Integrated pilot lamp and pilot lamp (H8) on the pump
control panel will illuminate.
◊
The pump control menu will be shown on display (N6).
Disengaging the water pump
- Let engine idle.
- Disengage the P.T.O. (Power Take Off) for the water pump:
◊
Press switch (S2).
◊
Integrated pilot lamp and pilot lamp (H8) on the pump
control panel extinguish.
Note:
If the P.T.O. was engaged from the rear pump control panel,
press switch (S2) once to activate the front display. Again press
switch (S2) to disengage the P.T.O. from the front display.
Engaging the P.T.O. I from chassis manufacturer installed P.T.O.
switch
- For further procedure please refer to chassis manufacturers
operation manual.
Note:
If the P.T.O. I was engaged from the chassis manufacturer
installed P.T.O. I switch it must be disengaged from there.
N6
S2
H8