![Rosenbauer 68206A-001 Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/rosenbauer/68206a-001/68206a-001_operation-manual_1487680083.webp)
Operation
83 / 97
Operation with water vapour cartridge
DE
EN
L03
L04
L05
L06
L07
L08
L09
L10
L11
L12
20.5 Operation with water vapour cartridge
CAUTION!
Stumbling risk!
When operating with water vapour cartridge the additional equipment
poses a stumbling risk.
When moving, pay attention to the surface.
20.5.1 Water mist operation
The water mist can be produced with high performance fan activated
and deactivated.
Water mist
Produce water mist without airflow
► Fold out stabiliser.
► Release stabiliser lock.
► Fold out stabiliser.
► Close stabiliser lock again.
► Connecting to a suitable water supply.
► The water supply hoses can be laid to the high performance fan
from behind.
Max 5 bar water pressure and approx. 200 l flow rate.
Water mist is produced.
Produce water mist with supplementary airflow
► Fold out stabiliser.
► Release stabiliser lock.
► Fold out stabiliser.
► Close stabiliser lock again.
► Connecting to a suitable water supply.
► The water supply hoses can be laid to the high performance fan
from behind.
Max 5 bar water pressure and approx. 200 l flow rate.
► Operate high performance fan.
Refer to chapter "Start high performance fan".
The water mist is fed with the airflow.