Reference Manual
00809-0100-4825, Rev BB
August 2005
A-11
Rosemount 248
Table A-5 continued
Code
Options
Extension Length
N050
50 mm (1.97-in.)
N115
115 mm (4.53-in.)
N130
130 mm (5.12-in.)
Stepped Stem Tubular Thermowells, 1.4571 (316 Ti) NAMUR–Compliant
G02
Thread Mount,
1
/
2
-in. BSPT (R
1
/
2
)
G04
Thread Mount,
3
/
4
-in. BSPT (R
3
/
4
)
G20
Thread Mount,
1
/
2
-in. BSPF (G
1
/
2
)
G22
Thread Mount,
3
/
4
-in. BSPF (G
3
/
4
)
G38
Thread Mount,
1
/
2
-in. NPT
G40
Thread Mount,
3
/
4
-in. NPT
L02
Flange Mount, 1-in. Class 150
H02
Flange Mount, DN 25 PN 16
H08
Flange Mount, DN 25 PN 25/40
H14
Flange Mount, DN 40 PN 25/40
Immersion Length
U075
75 mm (2.95-in.)
Additional Options Available
This data sheet contains a sample of the many temperature assembly options Emerson
Process Management has available. Refer to the following product data sheets or contact a
sales representative for more choices.
• Temperature Sensor and Accessories, Volume 1 (document number 00813-0100-2654)
• Temperature Sensor and Accessories, Volume 2 (document number 00813-0200-2654)
• Temperature Sensor and Accessories, Volume 3 (document number 00813-0301-2654)
U100
100 mm (3.94-in.)
U115
115 mm (4.53-in.)
U160
160 mm (6.30-in.)
U200
200 mm (7.87-in.)
U225
225 mm (8.86-in.)
U250
250 mm (9.84-in.)
U300
300 mm (11.8-in.)
U400
400 mm (15.7-in.)
Special Options
C1
Factory Custom Configuration of Alarm and Saturation Levels, Date, Descriptor and Message Field
A1
Analog Output Levels Compliant with NAMUR-Recommendations, NE43: High Alarm
CN
Analog Output Levels Compliant with NAMUR-Recommendations, NE43: Low Alarm
C4
5-Point Calibration (Use option code Q4 to generate a calibration certificate)
Q4
Calibration Certificate (3-Point standard; use option codes C4 with Q4 for a 5-Point Calibration Certificate)
F6
60 Hz line Voltage Filter
Q8
Thermowell Material Certificate
R01
Thermowell External Pressure Test
Typical Model Number:
248H
A
E1
A
1
ZR
N050
G22
U160
Q4
(1) The Rosemount 248H with CENELEC Type n Component Approval is not approved as a stand alone unit. Additional system certification is required.
Transmitters must be installed such that it is protected to at least the requirements of IP54.
(2) Consult factory for availability
(3) A
1
/
2
-in. thread adapter is used when Enclosure option code A or B is ordered with Sensor Type option codes ZR, ZJ, or ZK.
(4) Only specify this code if the sensor assembly is ordered though a separate model number (from one of the Sensor Product Data Sheets).
(5) Only available with Enclosure option code N.
Содержание 248
Страница 2: ......
Страница 4: ......
Страница 46: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 4 8 ...
Страница 64: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 A 18 ...
Страница 74: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 B 10 ...
Страница 77: ...Reference Manual 00809 0100 4825 Rev BB August 2005 0 1 Rosemount 248 NOTES ...
Страница 78: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 0 2 NOTES ...
Страница 79: ...Reference Manual 00809 0100 4825 Rev BB August 2005 0 3 Rosemount 248 NOTES ...