![Rose electronics ORION XC Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/rose-electronics/orion-xc/orion-xc_user-manual_1487128017.webp)
Orion XC Installation and Operations Manual
9
Parallel Operation (Stacking)
For special configurations, especially installations with more than one monitor per work station or
additional support of USB 2.0 transmission paths, the number of connectable CPUs and consoles can be
increased by a parallel operation (stacking) of several Orion XC devices.
One of the Orion XC matrices is configured as the master matrix. All the others must be configured as
slave matrix, with the IP address of the master matrix entered in the
Master IP Address
field. The slaves
must be connected to the master matrix via the network connector (RJ45) of the CPU board????, and the
Enable LAN Echi????
option must be activated at the master matrix.
If a switching command is executed in the OSD, the slave matrices will also switch automatically.
Switching of stacked devices might be delayed by several seconds.
Figure 9. Parallel Operation (Stacking)
1 - Dual-Head source (computer, CPU)
2 - CPU unit
3 - Interconnect cable
4 - Orion XC matrix (master matrix)
5 - Orion XC matrix (slave matrix)
6 - Network connection master / slave(s)
7 - CON unit
8 - Console (2x monitor, keyboard, mouse)