background image

52-51413   REV B 

 

2.7  MATERIALS 

 

Housing: 

 

 

 

 

Hard-Anodized Aluminum or 

 

 

 

 

 

Electropolished Stainless Steel 

 
Viewing Port:  

 

 

 

Polished Acrylic 

2.8  ENVIRONMENTAL 

 

Operating Temperature: 

 

 

0ºC to +50

o

C (32ºF to 122ºF) 

 

Storage Temperature: 

 

 

-20

o

C to +60

o

 

Depth Rating: 

 

 

 

70 m (230 ft) 

2.9  RS-485 CEX-HD CONNECTORS 

 
Hydrogroup LPMBH-6-MP (-01 configuration) 
Endbell Connector:   

 

 

Hydrogroup   LPMCBH-6-MP 

Inline Mating Connector:   

 

Hydrogroup  LPMCIL-6-FS 

 

Figure 1: LPMCBH-6-MP Face View 

Содержание RS-485 CEX-HD

Страница 1: ...B ROS RS 485 CEX HD 30 1 COLOR ZOOM CAMERA OPERATION AND MAINTENANCE MANUAL SERIAL NUMBER __________ SALES ORDER __________ 5618 Copley Drive San Diego CA 92111 7902 TEL 858 565 8500 FAX 858 565 8808...

Страница 2: ...52 51413 REV B II STANDARD ORDERING FORMAT FOR THE RS 485 CEX HD CAMERAS...

Страница 3: ...4 2 8 ENVIRONMENTAL 4 2 9 RS 485 CEX HD CONNECTORS 4 2 10 CAMERA INTERCONNECTIONS 5 3 CAMERA OPERATION 6 3 1 GENERAL 6 3 2 INSTALLATION 6 3 3 CAMERA BOOT UP SEQUENCE 7 3 4 EXPOSURE CONTROL 7 3 5 ZOOM...

Страница 4: ...his warranty shall be governed by the laws of the State of California In the event the defect is determined to be within the terms of this warranty then ROS agrees to repair and or replace at ROS disc...

Страница 5: ...sistance during installation and or operation of these products If you have any questions or problems with this product that are not covered by this manual or instruction please contact our agent in y...

Страница 6: ...52 51413 REV B VI CHANGE RECORD REV DESCRIPTION DATE A PRODUCTION RELEASE EC 03235 24AUG20 B SEE EC 03310 19JAN21...

Страница 7: ...ural but hostile environments The front window is made of impact resistant optical grade acrylic and utilizes a single O ring seal The RS 485 CEX HD camera utilizes a high resolution Exmor R CMOS imag...

Страница 8: ...Ratio 52 Db Video Output HD TVI Zoom Range 30 1 optical 4 3 to 129 0 mm focal length OR Digital Zoom 12x 360x with optical zoom combined Field of View In Air 71 3o Diagonal full wide angle 58 9oH x 45...

Страница 9: ...ual Manual uses direct iris position Video Negative Art Negates the video signal can help with contrast in some applications Video B W Transform the color video into black white video Image Flip Puts...

Страница 10: ...c 2 8 ENVIRONMENTAL Operating Temperature 0 C to 50o C 32 F to 122 F Storage Temperature 20oC to 60oC Depth Rating 70 m 230 ft 2 9 RS 485 CEX HD CONNECTORS Hydrogroup LPMBH 6 MP 01 configuration Endbe...

Страница 11: ...conn MCBHRA 8 MP Inline Mating Connector Subconn MCIL 8 F Figure 2 MCBHRA 8 MP Face View 2 10 CAMERA INTERCONNECTIONS CONNECTOR PIN FUNCTION 1 Camera Power Input 11 to 26 VDC 2 VDC Return 3 RS 485 A 4...

Страница 12: ...amage not covered under warranty For LPMBH 6 MP configuration 01 the logos will be aligned as shown in Figure 3 when the pins are aligned correctly Figure 3 Correct alignment of LPMBH 6 MP cable conne...

Страница 13: ...rol is desired due to unusual viewing conditions such as severe reflections or flashing lights the IC LINK must send a manual Exposure command followed by direct Iris position commands The operator no...

Страница 14: ...de all the time The one set of conditions which may force the operator to switch into Manual mode is when viewing a relatively close object that does not have much sharp detail This occurs because the...

Страница 15: ...isconnect your cable from the camera Then turn on the power and measure the voltage at the camera end of the cable according to your camera s pinout If there is no voltage or low voltage then you have...

Страница 16: ...cidental damage 5 3 CAMERA OPERATIONAL CHECKS Fuse F1 on the electronics interface board assembly should be checked for continuity F1 is a 1 25A 32VDC fuse element that protects the camera module from...

Страница 17: ...O ring should be given a light coating of silicone grease or other O ring lubricant before re assembly On the internal camera assembly ensure that all electrical connectors are correctly fitted and al...

Страница 18: ...52 51413 REV B 12 APPENDIX RS 485 CEX HD CAMERA DRAWINGS 52 51405 Top Assembly RS 485 CEX HD 52 51411 Installation RS 485 CEX HD 52 51412 Wiring Diagram RS 485 CEX HD...