11
TF 200.02.0026_eng
Water and drain placed in floor
If it is not possible to have the water supply and drain be placed in the wall, it is recommended to place it
within the hatched green area in the floor. The drain is Ø32.
Water and drain placed outside the lifting unit
If the water supply and the drain is placed outs-ide the lifting unit, it is recommended to make a cut-out in the
inner and outer covers, to allow water and drain to be brought inside the frame. If the height is adjusted
correctly in relation to the adjustment screws, see page 17, the height of the cut-out in the outer cover
mustn’t be greater than 27mm. The total height of the cut-out should not exceed 50mm.
The piping outside the lifting unit must be fixed, and should be brought inside the frame, as shown. Now,
connect the flexible pipes and hoses to the fixed piping. The fixed piping can be brought inside the frame
from both sides, but it is recommended to complete the installation in the right side.
50m
m
<=27m
m