![Ropox FlexiElectric 30-66-3 Series Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/ropox/flexielectric-30-66-3-series/flexielectric-30-66-3-series_user-manual-mounting-instructions_1486192007.webp)
Page 7
6.
Flexi electric Quickstart Guide
Checks:
•
Bolts are firmly tightened on the frame and into the wall
•
Stop rings and washers are in place on the spindle inside the legs
•
The spindle runs fully through each leg
•
There are no obstructions to full movement
Tips:
Upstand to worktop back to prevent items or
water flowing over
Space all around of 5mms
Control Box must be mounted
on
Underside of worktop
Check any potential gaps with
adjacent units or worktops
-either fill the gaps with fascia or
use
Ropox safety strips.
For adjacent adjustable frames a
Safety
Strip / Smartbox should be used
for each frame.
Press DOWN button first
Fascias on all
three sides
Recommendations:
•
Ropox recommendation is to always make use of fascias on all 3 sides
Start-up:
•
The frame must move freely and unimpeded throughout height adjustment. Check all connections of
flexible hoses, cables etc. to make sure none of these parts or other items are trapped when frame is
operated
Trouble shooting:
- No movement
– Check mains and power connection to control box
•
Check adapter cable with end resistor is connected correctly to control box
•
If frame is supplied with safety stop, remove/dismount connection to safety stop and replace yellow
end resistor. If frame moves downwards now, safety stop has to be examined to check if it is activated,
has been bend with a radius of less than 20mm or has been damaged
•
Check if label on control box describes a Flexi control with either 1 or 2 motors, corresponding to
number of motors on the frame
•
If you hear several
“clicks” when connecting to main power it means plugs between control box,
motors and control switch are not connected correct or pushed/plugged right in (under normal
circumstances
the control box would “click” twice)
•
Before use:
•
If these frames are mounted/installed or rebuild together with other electrical components, the whole
product will be looked at as a new unit and must therefore undergo risk assessment, by which it can
receive CE-marking