Set the DIP switch 15to the proper secondary voltage range.
With extremely high secondary currents (larger than 80A)
DIP switch No.5must also be on.
NOTE:
5. OPERATING INSTRUCTIONS
5.1
5.2
5.3
Examine the controller and determine that the power to be supplied to the
controller is in agreement with the controller´s voltage specification.
50Hz
50H
z
60H
z
60Hz
50Hz
60Hz
Position the Jumper 13
to select 50 or 60Hz
frequency
1
1
2
2
3
3
4
4
5
5
ON
ON
1
2
3
4
5
Switch
No.
20-60
3- 10 8- 30
50-80
U
2
V
( )
12
13
14
15
U
U
1
2
PRIM.
SEK.
NETZ
SCH
W
EISSTR
AFO
LINE
V
Hz
50 / 60
Example:
With a secondary voltage of 42V and a start up current of 120A ( I max = U / R )
the DIP switch 3 and 5must be on.
2
2
HL
3
15
1
13
5
4
6
7
2
Dip Switches to
select U range
2
Potentiometer to select
Seal Temperature
(10 turn Pot)
Temperature Indicator
°C
"Z" point = 20°C
Jumper to
select Frequency
50 or 60Hz
LED red
blinks in measuring mode,
glows continuously when
controller is operating in
the regulating mode.
"HAND" Push Button
Starts the Controller
Reset Button after
an Alarm shutdown
LED red
when there is a
malfunction
10-turn Potentiometer
for "Z" calibration
(needle at "Z")