9. TECHNICAL SPECIFICATIONS
Type of Construction
:
Line Voltage
:
Frequency
:
Temperature Control
:
Start Signal
:
Alarm Output
:
Sampling rate
:
Calibration
:
Max. Primary Current
:
Housing designed for mounting into the front panel
Standard 230 VAC; 115or 400VAC optional
(allowable deviation -10%
+15% )
50 or 60Hz; selected with jumper
(allowable deviation ±1Hz )
10 Turn potentiometer, temperature range 0 - 300°C (0 - 500°C)
Voltage level across 3 and 4 : OFF: 0-2 VDC; ON: 5-30VDC; typ. 8mA / 24VDC
or
Contact between 2 and 7: OFF: Contact open; ON: Contact closed; typ.0.13mA
Potential free contact, max. 50V/0,2A
Contact closed when Alarm signal on
Every tenth cycle of line voltage in the calibration mode.
200msec at 50Hz / 166msec at 60Hz
Every voltage cycle in controlling mode
20msec at 50Hz / 16.6msec at 60Hz
Calibrated for Heatseal Bands with T = +10 10 K
K
x
-4
-1
Operating
Mode
Constant heat
Impulse
with 20% Duty cycle
TYPE
RES-22X-0
(Standard)
RES-22X-1
5A
25A
15A
20A
Main Application
Ambient Temperature
:
Electrical connection
:
Protective Cathegory
:
Weigth
:
+5°C...+45°C (+41°F...+113°F)
terminal blocks, with plug in connectors
IP 20
RES-220 Controller
1.06 kg (2.33 lbs)
RES-221 Controller
1.22 kg (2.69 lbs)
Current transformer 0.15kg (0.33 lbs)
Current transformer and electrical connectors included with controller