Factory settings
UPT-640 (as of SW 100)
51
10
Factory settings
The CIRUS temperature controller UPT-640 (as of SW
100) is configured in the factory as follows:
Values in the Settings
and Configuration
menus
Settings menu
No. 101
Heatsealing temperature: 0°C
No. 102
Preheating temperature: 0°C
No. 103
Starting delay:
0s
No. 104
Heatsealing time:
0.10s
No. 105
Cooling value:
Cooling time:
1.00 s
Absolute cooling temperature: 50°C
Relative cooling temperature:
40 % of heatsealing temperature
No. 106
Hold mode:
OFF
No. 107
AUTOCAL temperature: 20°C
No. 110
Correction factor Co:
100%
No. 115
Release temperature:
0°C
No. 116
Release delay.
0s
No. 117
Release duration:
0s
Configuration menu
No. 201
Language
German
This selection is NOT changed if the factory settings are
restored with step 202 in the Config. menu.
No. 203
Alloy
1700ppm
No. 204
Temperature range:
max. 300°C
No. 206
Maximum temperature: 300°C
No. 207
Set point reached:
-10K
No. 208
Set point exceeded:
+10K
No. 209
Time control:
OFF
No. 210
Cooling mode:
Absolute
No. 212
Relay K1 function:
Active when temperature reached
No. 213
Lock of „HAND“ key
OFF
No. 214
Cycle counter:
0
No. 215
Alarm relay:
Normal (contact closed by a fault)
No. 216
Analog output:
Actual temperature
No. 217
Temperature diagnosis: OFF
No. 218
Temp.diagnosis
delay time:
0s
No. 219
Heatup timeout:
OFF
No. 220
Measuring impulse length:Standard (1.7ms)
No. 221
Autocomp:
OFF
No. 222
"Output 1":
Active if Tact = Tset, with latch function
No. 224
Starting temperature:
100°C
No. 225
Temperature unit:
Celsius