Controller functions
UPT-640 (as of SW 100)
29
9.5
Two-digit numbering system
up to software revision 022
A system of one and two-digit numbers was used for
the Settings and Configuration menus up to software
revision 022. Three-digit numbers were introduced in
software revision 100 to improve the clarity of the menu
structure.
The table below compares the two numbering systems:
All numbers or menu steps not listed above
are only available as of software revision 100
and are described in chap. 8 „Startup and opera-
tion“, page 17 (and section 9.4 "Menu structure" on
page 27 respectively).
Menu
Menu steps
Numbering
up to software
revision 022
Numbering
as of software
revision 100
Settings menu
Heatsealing temperature
2
101
Starting delay
3
103
Heatsealing time
3
104
Cooling value
4
105
Hold mode
5
106
AUTOCAL
1
107
Correction factor Co
6
110
Release temperature
10
115
Release delay
11
116
Release duration
12
117
Configuration menu
Language
30
201
Factory settings
31
202
Alloy / TCR
32
203, 204
Maximim temperature
33
206
Set point reached
35
207
Set point exceeded
36
208
Time control
37
209
Cooling mode
38
210
Relay K1 function
39
212
Cycles
42
214
Alarm relay
43
215
Analog output
34
216
Starting temperature
40
224
No longer available
menus
Cycle configuration
20
---
Hand impulse
21
---
!