Installation
UPT-640 (as of SW 100)
13
7.3
Power supply
ROPEX
temperature
controller
UR
IR
R
PRIM.
U1
Kb
Ka
SEC.
U2
LINE
I
>
I
>
GND/
Earth
N (L2)
L1 (L1)
LINE
FILTER
ON
OFF
Kc
3
3
3
1
Short wires
2
2
Line
400VAC
50/60Hz
Over-current protection
Double-pole circuit-breaker or fuses,
(
ROPEX Application Report)
Short-circuit protection only.
CIRUS temperature controller not protected.
!
Relay Ka
For "HEAT ON - OFF" function (all-pole) or
"EMERGENCY STOP".
Line filter
The filter type and size must be determined according to
the load, the transformer and the machine wiring
(
ROPEX Application Report).
Do not run the filter supply wires (line side) parallel
to the filter output wires (load side).
!
CIRUS temperature controller
belonging to the 6xx
Series.
Relay Kb
Load break (all-pole), e.g. in combination with the alarm
output of the temp. controller (ROPEX recommendation).
When using a series resistor RV-....-1 the relay Kb
shall be installed.
!
Impulse Transformer
Designed according to VDE 0570/EN 61558 (isolating
transformer with reinforced insulation). Connect core to
ground.
Use transformers with a one section bobbin. The
power, duty cycle and voltage values must be deter-
mined individually according to the application (
ROPEX
Application Report and "Accessories" leaflet for impulse
transformers).
!
Wiring
The wire cross-sections depend on the application
(
ROPEX Application Report).
Guide values:
Primary circuit:
min. 1.5mm², max. 2.5mm²
Secondary circuit: min. 4.0mm², max. 25mm²
These wires must always be twisted (>20turns/meter).
These wires must be twisted (>20turns/meter)
if several control loops are laid together ("crosstalk").
Twisting (>20turns/meter) is recommended to
improve EMC.