Toggle Temperature Type

 

Instantly toggle displayed temperature units from Fahrenheit to Celsius or vice versa by pressing on the 
displayed temperature reading on the home screen. 

>Home

 

Password-Protected Access Tiers: Certifier & EH&S

 

Password protected access tiers enable advanced configuration options and features. 

Home> Settings>System>Advanced>Change Passwords

 

USB Interface for Field Upgrade Procedure

 

Firmware upgrades can be installed on-site via USB flash drive. 

Customizable Boot Screen

 

Our engineers can configure your unit with a custom image or logo file (240x320) in portable network 
graphic (.png) format to display on bootup. Contact our sales team to get started: 

[email protected]

 

Night Setback

 

EH&S or Certifier users can configure 3 convenient modes (Audible, Muted, or Off) of operation.  
The Rooster

TM

 Sensor100 is a N/O device, to trigger audible or muted night setback, the dry contact relay 

must be closed. See Page 10 for instructions on how to setup night setback alarm thresholds. 

Home> Settings>System>Alarms/Sound>Alarm Controls>Night Setback

 

Alarm Latching

 

EH&S or Certifier users can setup latched alarms to indicate that a low airflow state has occurred in the 

Alarm Controls

 menu. User must

 then enter EH&S or Certifier passcode to unlatch an alarm. 

Home> Settings>System>Alarms/Sound>Alarm Controls>Latch Alarm

 

Alarm Ringback

 

EH&S or Certifier users can configure the amount of snooze time before an alarm rings again after being 
muted 

in the 

Alarm Controls

 menu.

 

Home>Settings>System>Alarms/Sound>Alarm Controls>Ringback 

Backlight Dimming 

Users can toggle the brightness setting, as well as the brightness of the screen when set to “dim”. 

 

A “time before dim” option is available that sets the screen to dim after a predetermined amount of time 

has expired. 

Home> Settings>System>Brightness

 

Airflow Resolution 

EH&S or Certifier users can select the resolution of air velocity units displayed in m/s, fpm, or cfm  

Note

: cfm can only be displayed once duct diameter information has been entered; see page 13 of this 

manual for more information. 

Home>Settings>System>Advanced>Airflow Resolution 

 

 
 
 
 

Содержание Sensor 100

Страница 1: ...proprietary information of Degree Controls Inc contents are protected under US copyright laws Degree Controls Inc 2016 High Performance Air Velocity and Temperature Sensor with Full Color Touch Screen...

Страница 2: ...RoosterTM Sensor100 8 Probe Sensor 8 Night Setback Input 8 Boot Up Procedure 9 Access Tier Privileges USER EH S CERTIFIER 9 Set Change Passwords 10 Alarm Threshold Configuration 10 Alarm Troubleshoot...

Страница 3: ...it display and contains many simple to use features and configuration capabilities built into an intuitive user interface that requires little to no training to learn Password protected access tiers e...

Страница 4: ...through low medium or high alarm volumes If logged in as an EH S or Certifier a global minimum volume threshold can be set This restricts a standard User from setting an alarm volume too low for parti...

Страница 5: ...ust be closed See Page 10 for instructions on how to setup night setback alarm thresholds Home Settings System Alarms Sound Alarm Controls Night Setback Alarm Latching EH S or Certifier users can setu...

Страница 6: ...Operating temperature 40 F 140 F 5 C 60 C Storage temperature 40 F 185 F 40 C 85 C Weight 6oz 170g Compliance Standards CE RoHS Rear Panel View of RoosterTM Sensor100 Connection Description Connector...

Страница 7: ...er to be recessed and sit approximately 0 6 15mm proud of the mounting surface 1 Wall mount backplate For installations where the Rooster Sensor100 is mounted directly to a flat surface the Wall mount...

Страница 8: ...as pictured above The RoosterTM Sensor100 has additional input and output capabilities for night setback and alarm output relay The IO connectors present on the RoosterTM Sensor100 have some pins deac...

Страница 9: ...The RoosterTM does not have a power on switch and will become energized as soon as you plug it in The RoosterTM boots to the screen depicted on the right with a slot for a custom logo The boot screen...

Страница 10: ...ust Thresholds 2 To set alarm thresholds you will first have to define an alarm trip point and an alarm clear point The alarm trip point is the air velocity value that will trigger an alarm The alarm...

Страница 11: ...rflow drops below NSB trip point To adjust Night Setback alarm thresholds you must go to the Threshold menu and select Adjust Thresholds Muted Enters Night Setback mode whenever relay is closed and tr...

Страница 12: ...ccurred If the latch alarm setting is set to Password mode an EH S passcode must be entered to unlatch this alarm If the Latch alarm setting is set to ON simply tap the banner to disable the alarm Swi...

Страница 13: ...anced users displayed velocity units can be configured to display in an alternate resolution The default resolution for units is 1 fpm and 01 m s respectively however for users who prefer a more unifo...

Страница 14: ...urther information Home Settings System Advanced I O Polarity DAC Output The RoosterTM Sensor100 has DAC Output enabled with correspondence to air velocity There are four user selectable ranges to cho...

Страница 15: ...irmware 5 When you have completed the Factory Reset Procedure navigate to the info screen from home to validate that your new firmware version was properly installed The date of the firmware release l...

Страница 16: ...he RoosterTM Sensor100 is warranted to be free from defects in workmanship and materials for a period of one 1 year from receipt Degree Controls will at its option replace or repair defective parts wi...

Отзывы: