background image

AIR COMPRESSOR

12

leading to possible serious personal injury.

WARRNING!

Do not connect to power supply until assembly is complete. 
Failure to comply could result in accidental starting and possible 
serious personal injury.

.

CHECKING THE OIL 

Always check the oi; when the unit is sitting on a level surface 

and before first use.

1) The sight glass is located above the tank. There is a red dot 
in the center of the glass.
2) An oil level at the top of the red dot indicates oil is at maximum 
level.
3) An oil level at or below the bottom of the red dot indicates oil 
is below desired level, and oil should be added

TO ADD OIL:

1) Unscrew the cap of oil fill hole.
2) Using a funnel, carefully pour oil into the oil fill hole.
3) Tighten the cap securely into the oil fill hole.

NOTE:

Avoid too much oil. Ensure that the level of the oil does not exceed 
the top of red dot at sight glass.

10

Содержание RC-5010

Страница 1: ...AIR COMPRESSOR 50LITER RC 5010...

Страница 2: ......

Страница 3: ...USER MANUAL 3 PARTS LIST 1 ON OFF switch 2 Handle 3 Safety switch 4 Power cord 5 Drain valve 6 Coupler 7 Pressure gauge 8 Pressure regulator 9 Filter 10 Motor housing 11 Sight glass 12 Oil fill hole 1...

Страница 4: ...or battery operated Cordless Power tools WORK AREA SAFETY Keep work area clean and well lit Cluttered or dark areas invite accidents Don t operate power tools in explosive atmospheres such as in the p...

Страница 5: ...ectric shock When operating a power tool outdoors use an extension cord suitable for outdoor use Using a cord suitable for outdoor use will reduce the risk of electric shock If operating a power tool...

Страница 6: ...on facilities ensure these are connected and properly used Use of dust collection can reduce dust related hazards POWER TOOL USE AND CARE Don t force the power tool Use the correct power tool for your...

Страница 7: ...afety of power tool is maintained Follow instruction for lubricating and changing accessories Keep handles dry clean and free from oil and grease AIR COMPRESSOR USE AND CARE Do not exceed the pressure...

Страница 8: ...moisture after each day s use If unit will not be used for a while it is best to leave drain valve open unit such time as it to be used This will allow moisture to completely drain out and help preve...

Страница 9: ...ding Always follow all safety rules recommended by the manufacturer of your air tool in addition to all safety rules for the air compressor Following this rule will reduce the risk of serious personal...

Страница 10: ...with air connected Storing the tool with air connected can result in unexpected firing and possible serious personal injury Protect your lungs Wear a face or dust mask if the operation is dusty Follo...

Страница 11: ...ny parts on the packing list are already assembled to your product when you unpack it Use of a product that may have been improperly assembled could result in serious personal injury Inspect the produ...

Страница 12: ...glass is located above the tank There is a red dot in the center of the glass 2 An oil level at the top of the red dot indicates oil is at maximum level 3 An oil level at or below the bottom of the r...

Страница 13: ...zles and tire inflators TO MOVE THE AIR COMPRESSOR Ensure the air compressor is unplugged make sure the power cord is secured in the cord warp 1 Facing the back of the air compressor grasp the handle...

Страница 14: ...ut off again when the desired pressure is reached WARNING Never exceed the air tool s pressure rating as recommended by the manufacturer When using this air compressor as an inflation device always fo...

Страница 15: ...ng counterclockwise reduces air pressure at the outlet 8 Following all safety precautions in the air tool manual You may now proceed to use your air powered tool WARNING Air powered tools may require...

Страница 16: ...N 1 Turn the air compressor off 2 Pull the ring on the pressure relief valve to release until pres sure gauge reads less than 1 4 bar 3 Release the ring 4 Rotate drain valves counterclockwise to open...

Страница 17: ...ompressor on and allow the tanks to fill The compressor will shut off when the pressure reaches the preset maximum 2 Turn the air compressor off 3 Pull the ring on the safety valve to release air for...

Страница 18: ...of air compressor maintenance it is also advised that the oil is routinely checked for proper levels WARNING Do not at any time let brake fluids gasoline petroleum based products penetrating oils etc...

Страница 19: ...ilter cover and secure it by turning it clockwise CHANGING THE OIL Replace the oil after the first 10 hours of operation and every 100 hours following the oil change The sight glass located above the...

Страница 20: ...er Shop house breaker open Replace shop house blow fuse Current limiting protector open Reset shop house breaker determine why problem happened Pressure switch bad Motor will restart when cool Tank is...

Страница 21: ...sture in Discharge air Excessive water in air tanks Drain tanks High humidity Move to area of less humidi ty use air line filter Compressor runs continu ously Defective pressure switch Take compressor...

Отзывы: