safety warnings 

For your own and other’s safety please read this USER’S MANUAL and follow its instructions 
carefully.  

 

Danger 

1

Never  use  the  heater  where  flammable  vapors  may  be  present,  there  is  danger  of 

explosion, fire and burning. 

2

Always  provide  adequate  ventilation  during  the  use.  Only  use  the  appliance  in  well 

ventilated  area,  the  air  must  be  regular  exchanged  during  the  use  (two  times/one  hour, 
inadequate burning caused by oxygen shortage can cause carbon monoxide poisoning. 

 Warning 

1

It’s  need  a  standard  reducer  and  hose  when  you  use  this  machine.  (specification  of 

reducer

pressure Pu=700mbar

flow rate Qn=1.5kg/h

 

2

D

on’t use spay products at the location where the heater is used

the gas from the spay tin 

can cause danger of fire and explosion. 

3

Don’t  use  the  appliance  in  place  with  combustible  powder

wastepaper,  wood  crumbs, 

fibre scraps

if these powder are sucked in the heater and heated up, flake and spark may 

be ejected out and cause fire and burning danger. 

4

Never block air inlet or heating part

it can cause abnormal burning and fire. 

5

Never modify the heater, alteration may cause malfunction and fire, is very dangerous. 

6

Don’t expose the appliance to rain or snow, never use it in humidity places either. Pull out 

the plug before the routine maintenance and examination. 

 

Attention 

1

 

In order to prevent fire while in operation, please don’t place articles near the heater. Keep 
all combustible materials away from heater. Minimum clearances: Outlet (front) 2.5M

air 

inlet (rear) 2M

top 2M

side 2M. 

2

 While  in  operation

make  sure  that  the  ground  surface  does  not  overheat

overheating 

may cause fire. 

3

  Do  not  fill  fuel  tank  while  heater  is  in  operation,  make  sure  the  heater  stopped  and  the 

flame  extinguished  before  you  fill  the  tank.  Filling  while  in  operation  may  result  causing 
fire. 

3

 

Before  use  the  appliance,  make  sure  that  the  voltage  and  frequency  on  site  is  in 
accordance with the ones shown on rating plate.

 

 

Содержание K-15

Страница 1: ...nd operate following the operation instructions in this manual in order to prevent fire or other accidental danger Keep this manual in a safe place for future reference Any understanding problem relates to this manual please contact your dealer Warning During operation always provide adequate ventilation and keep a 2 5 m safety distance away from combustible articles HEATER K 15 Réf 93449 User s M...

Страница 2: ...uction of products 3 Overview of appliance 3 Introduction of pressure reducing value and hose 4 Dimensions 4 Technical data 4 Operation instructions 5 gas supply circuit 7 electric circuit 8 Exploded parts drawing 9 Parts name 9 Trouble shooting 11 ...

Страница 3: ...e powder are sucked in the heater and heated up flake and spark may be ejected out and cause fire and burning danger 4 Never block air inlet or heating part it can cause abnormal burning and fire 5 Never modify the heater alteration may cause malfunction and fire is very dangerous 6 Don t expose the appliance to rain or snow never use it in humidity places either Pull out the plug before the routi...

Страница 4: ... electromagnetic control device which enables power shutoff flame failure and overheating protections The three kinds of protections prevent the gas leakage and potential carbon monoxide poisoning and fire danger induced by gas leakage 3 A gas rate adjustment valve is installed in this product so the heat input can be regulated to fulfill variable requirements at different locations Overview of ap...

Страница 5: ...e Qn 1 5kg h Please try to use the reducer as the same as or the similar the picture Dimensions Technical data Gas pressure Rated voltage Motor power input Max gas consumption Max heat input ot air output 0 7bar 230V 50Hz 25W 1 11 Kg h 15KW 300m3 h Connection hose hose screw thread which connected with this heater is G3 8 left Connected with the reducer reducer gas filling valve Connected with gas...

Страница 6: ...gain Figure 3 4 Set the regulator to the maximum setting Figure 4 5 Make sure the machine is proper connected with the gas cylinder and the power switch is at the OFF O position plug the power plug in the socket outlet shut on the power switch put the power switch at the ON 1 position Figure 5 6 When the turning of the fan blades becomes stable use the right hand to push the aluminum handspike of ...

Страница 7: ...condition There is explosion danger caused by high gas concentration Contact your dealer in time to clear the reason of malfunction Tighten the connector according to the arrowhead direction Tighten the connector according to the arrowhead direction Open the gas supply tap according to the arrowhead direction Press down the pressure regulator Put the power switch at position 1 Ignite ...

Страница 8: ...and burning at the burning head 7 Current occurs in the thermocouple due to the heat output by gas burning 8 The thermostat activates an electric circuit to enable the small electromagnetic valve in the flameout protector magnetizing the armature of flameout protection valve the gas passes through and burns continuously Item Parts name 1 Gas inlet connector 2 Flame failure protector 3 Electromagne...

Страница 9: ... valve circuit Ignition circuit Flameout protection circuit B thermostat G integral electromagnetic valve in the flameout protector M fan motor Q power switch Q2 igniter S ignition needle S2 thermocouple Y electromagnetic valve C capacitor Page 7 ...

Страница 10: ...Page 9 Exploded parts drawing Parts name item name 1 Front grid 2 Heat insulation plate 3 Enclosure 4 Plastic handle Page 8 ...

Страница 11: ...e seat 15 Connector 16 Adjustment valve 17 Plastic knob 18 Fixation nut M12 P1 0 19 Fixation nut M12 P1 0 20 Lameout protector 21 Electromagnetic valve 22 Gas inlet connector 23 Fixation nut for gas inlet 24 Protection guard 25 Fixation nut for igniter 26 Igniter 27 Power switch 28 Control box 29 Cord fixation head 30 Power cord 31 Cap connector 32 Copper tube 33 Burning head 34 Thermocouple clip ...

Страница 12: ...andspike was not pushed to proper position Push the handspike to proper position Gas exhausted Replace the gas cylinder Power failure Re ignition after the power recovers The knob was not set at maximum setting Adjust the knob to maximum setting The knob was not set in the proper setting position Adjust the knob setting Thermostat operated Remove the cause after the heater cools down then ignite a...

Отзывы: