Trouble shooting 

Problem

 

Heater 

does not 

start 

Heater 

does not 

ignite 

Flameout 

while 

burning 

Insufficient 

heat input 

Solution 

No power 

 

 

 

 

Make sure the 
power is proper 
connected 

Low voltage 

 

 

 

 

Resolve the 
problem which 
causes low voltage  

Flame failure 
protection 
handspike was not 
pushed to proper 
position 

 

 

 

 

Push the 
handspike to 
proper position 

Gas exhausted 

 

 

 

 

Replace the gas 
cylinder 

Power failure 

 

 

 

 

Re-ignition after 
the power 
recovers 

The knob was not 
set at maximum 
setting 

 

 

 

 

Adjust the knob to 
maximum setting 

The knob was not 
set in the proper 
setting position  

 

 

 

 

Adjust the knob 
setting 

Thermostat 
operated 

 

 

 

 

Remove the cause 
after the heater 
cools down, then 
ignite and operate 
the heater 

Others  

 

 

 

 

Contact service 
personal or your 
dealer 

 

 

Содержание K-15

Страница 1: ...nd operate following the operation instructions in this manual in order to prevent fire or other accidental danger Keep this manual in a safe place for future reference Any understanding problem relates to this manual please contact your dealer Warning During operation always provide adequate ventilation and keep a 2 5 m safety distance away from combustible articles HEATER K 15 Réf 93449 User s M...

Страница 2: ...uction of products 3 Overview of appliance 3 Introduction of pressure reducing value and hose 4 Dimensions 4 Technical data 4 Operation instructions 5 gas supply circuit 7 electric circuit 8 Exploded parts drawing 9 Parts name 9 Trouble shooting 11 ...

Страница 3: ...e powder are sucked in the heater and heated up flake and spark may be ejected out and cause fire and burning danger 4 Never block air inlet or heating part it can cause abnormal burning and fire 5 Never modify the heater alteration may cause malfunction and fire is very dangerous 6 Don t expose the appliance to rain or snow never use it in humidity places either Pull out the plug before the routi...

Страница 4: ... electromagnetic control device which enables power shutoff flame failure and overheating protections The three kinds of protections prevent the gas leakage and potential carbon monoxide poisoning and fire danger induced by gas leakage 3 A gas rate adjustment valve is installed in this product so the heat input can be regulated to fulfill variable requirements at different locations Overview of ap...

Страница 5: ...e Qn 1 5kg h Please try to use the reducer as the same as or the similar the picture Dimensions Technical data Gas pressure Rated voltage Motor power input Max gas consumption Max heat input ot air output 0 7bar 230V 50Hz 25W 1 11 Kg h 15KW 300m3 h Connection hose hose screw thread which connected with this heater is G3 8 left Connected with the reducer reducer gas filling valve Connected with gas...

Страница 6: ...gain Figure 3 4 Set the regulator to the maximum setting Figure 4 5 Make sure the machine is proper connected with the gas cylinder and the power switch is at the OFF O position plug the power plug in the socket outlet shut on the power switch put the power switch at the ON 1 position Figure 5 6 When the turning of the fan blades becomes stable use the right hand to push the aluminum handspike of ...

Страница 7: ...condition There is explosion danger caused by high gas concentration Contact your dealer in time to clear the reason of malfunction Tighten the connector according to the arrowhead direction Tighten the connector according to the arrowhead direction Open the gas supply tap according to the arrowhead direction Press down the pressure regulator Put the power switch at position 1 Ignite ...

Страница 8: ...and burning at the burning head 7 Current occurs in the thermocouple due to the heat output by gas burning 8 The thermostat activates an electric circuit to enable the small electromagnetic valve in the flameout protector magnetizing the armature of flameout protection valve the gas passes through and burns continuously Item Parts name 1 Gas inlet connector 2 Flame failure protector 3 Electromagne...

Страница 9: ... valve circuit Ignition circuit Flameout protection circuit B thermostat G integral electromagnetic valve in the flameout protector M fan motor Q power switch Q2 igniter S ignition needle S2 thermocouple Y electromagnetic valve C capacitor Page 7 ...

Страница 10: ...Page 9 Exploded parts drawing Parts name item name 1 Front grid 2 Heat insulation plate 3 Enclosure 4 Plastic handle Page 8 ...

Страница 11: ...e seat 15 Connector 16 Adjustment valve 17 Plastic knob 18 Fixation nut M12 P1 0 19 Fixation nut M12 P1 0 20 Lameout protector 21 Electromagnetic valve 22 Gas inlet connector 23 Fixation nut for gas inlet 24 Protection guard 25 Fixation nut for igniter 26 Igniter 27 Power switch 28 Control box 29 Cord fixation head 30 Power cord 31 Cap connector 32 Copper tube 33 Burning head 34 Thermocouple clip ...

Страница 12: ...andspike was not pushed to proper position Push the handspike to proper position Gas exhausted Replace the gas cylinder Power failure Re ignition after the power recovers The knob was not set at maximum setting Adjust the knob to maximum setting The knob was not set in the proper setting position Adjust the knob setting Thermostat operated Remove the cause after the heater cools down then ignite a...