5
www.romus.fr
THERMO HYGROMETRE BC-05
REF. 93232
04. Operating panel
1. Sensor for relative humidity and air temperature
2. On/off button
3. MAX/MIN button
4. LCD
r&r) EXWWRQ ,QWHUQDO
‚switch‘, switchable with
DQHHGOH
1.
ŕ/RZEDWWHU\œV\PERO
2. MAX or MIN symbols
5+6\PERO
4. Display of the measured value for
relative
humidity
r&r)V\PERO
6. Automatic power-off symbol
7. Display of measured value for tem-
perature
1
2
3
4
1
2
3
4
5
7
6
05. Operation
Switching on/off:
Press the on/off button to switch the measuring instrument on or
off respectively.
Relative humidity and air temperature measurements
+ROGWKHVHQVRULQWKHDUHDWREHPHDVXUHGDQGDOORZWKHPHDVX
ring instrument sufficient time to obtain a stable measured value.
7KHPHDVXUHGYDOXHVDUHDXWRPDWLFDOO\GLVSOD\HGLQr&7KHGLVSOD\
FDQEHFKDQJHGIURPr&WRr)YLDDVZLWFKLQWKHEDWWHU\FRPSDUW
ment. To access the switch, open the battery compartment and re-
move the battery. You can now see an opening at the upper edge of
the inside of the appliance, from which the battery connecting cables
lead. The switch is located immediately behind
the opening. The switch can easily be switched
with the aid of a thin needle.
5HDGRIIWKHUHODWLYHKXPLGLW\RUWKHDLUWHPSH
rature as the case may be.
Do not immerse the measuring instrument in liquids. It is
intended exclusively for measurements in air.
Moving the appliance from a cold to a warm environment
(and vice versa) can lead to the formation of condensation
on the measuring circuitry of the appliance. This physical
effect, which cannot be prevented by structural means for
any measuring instrument, leads to false measurement
values. Depending on the temperature difference, the app-
liance requires an ‚acclimatisation time‘ of approx. 15 - 30
minutes before the measuring procedure can be resumed.
D
Minimum (MIN) maximum (MAX) function
Using the MIN/MAX mode you can read off either the highest or
the lowest value.
3UHVVWKH0,10$;EXWWRQRQFHWKHŕ0$;œV\PERODSSHDUVRQWKH
display. The LCD now displays the highest value of the previously
selected parameters. This value appears until a higher value is
measured.
3UHVVWKH0,10$;EXWWRQDJDLQWKHŕ0,1œV\PERODSSHDUVRQ
the display.
7KLVYDOXHDSSHDUVXQWLODORZHUYDOXHLVPHDVXUHG7RH[LWIURPWKLV
PRGHSUHVVDQGKROGWKH0,10$;EXWWRQIRUDSSUR[VHFRQGV
7KHŕ0$;œRUŕ0,1œV\PEROQRORQJHUDSSHDUVRQWKHGLVSOD\
06. Battery replacement
,IWKHŕ
- +
ŕV\PERODSSHDUVRQWKH/&'WKLVPHDQVWKDWWKHEDW
-
tery must be replaced. Open the battery compartment. To do this,
gently depress the cover on the rear side and push it in the direc-
WLRQRIWKHDUURZVKRZQRQWKHƃDS&DUHIXOO\UHOHDVHWKHEDWWHU\
FOLSDQGUHSODFHWKHVSHQWEDWWHU\ZLWKDQHZ9EDWWHU\1('$
9EDWWHU\)RUHTXLYDOHQW)LWWKHEDWWHU\FRPSDUWPHQW
lid again. The appliance is now ready for operation once more.
Electronic equipment may not be disposed of as do-
mestic waste, but must be correctly disposed of in
accordance with the EUROPEAN PARLIAMENT AND
(8523($1&281&,/'LUHFWLYH(&RI-D
-
nuary 2003 regarding used electrical and electronic
equipment. Please dispose of this equipment in accordance with
the applicable legal regulations when its service life is ended.
GB