21
RolliBot RolliCOOL 208-20V2 Portable AC User Manual
Section 7. Storage
Store your RolliCool 208-20V2 in a dry, indoor environment. Properly storing your RolliCool will
help improve performance and product lifespan.
Step 1.
Turn off and unplug the AC unit.
Step 2.
Remove the exhaust hose and window kit as needed for storage with the unit.
Step 3.
Remove, clean, then reinstall the air filters.
Step 4.
Drain the unit of any water and ensure all parts are completely dry.
Step 5.
Turn the unit on and run it in fan mode at the lowest speed for at least two hours to
ensure the inner reservoir is completely dry.
Step 6.
Turn off and unplug the unit and install the power cord’s plug into its fixture on the back
of the unit.
• Always turn off and unplug the unit before transporting or storing.
• Cover the unit and close all vents to protect it from dust. Do not store in a dusty environment. As with all electronic devices,
dust may cause damage over time.
• Store the unit indoors at a dry and stable temperature. Do not store in an unheated garage, shed, or other locations with
extreme temperature fluctuations.
Section 8. Troubleshooting
Problem
Possible Cause(s)
Solution(s)
The unit does
not power on.
There is no electricity.
Turn it on after connecting it to a socket
with electricity.
The overflow indicator is on.
Drain the water inside.
The system is protected
Wait 3 minutes until the temperature is
lowered then restart the unit.
The cooling
effect is weak.
There is direct sunlight.
Cover any direct sunlight coming
through the windows.
Doors or windows are open; there
are a lot of people; or there are
other sources of heat nearby.
Close doors and windows.
The filter is dirty.
Clean or replace the filter.
The air inlet or outlet is blocked.
Clear obstructions.
Excessive noise The unit is not placed on a flat
surface.
Place the unit on a flat and stable surface.
Leaking while
moving
Water reservoir is full.
Drain the water reservoir before moving
(see
Section 6.2 How to Drain the Unit
).
The drainage plug may be cracked. Check the drain stop plug for cracks
Display not on
Power plug and socket contact
bad or power cord disconnect, no
power.
Check the power plug, power cord or
socket and connect it again.
There is unusual
sound
It is normal to have a slightly
stronger vibration sound in the first
few minutes after power-up.
Will disappear after few minutes.