background image

© 2015 Rollease Acmeda

Page. 10 of 12

3.9 ACTIVATE / DEACTIVATE FABRIC TENSION MODE

3.10 SWITCHING BETWEEN AUTO & MANUAL LOCK MODE

 = TENSION MODE ON 

 = TENSION MODE OFF

Beep

Beep

x 1

x 2

P2   

STOP

DOWN  

 = AUTO LOCK

 = MANUAL LOCK

Beep

x 2

x 5

P2   

UP

UP

Fabric Tension Mode must be ON to switch between Auto & Manual Lock Mode

3.11 ADJUSTING TENSION LEVEL

P2   

UP

STOP

 = LOW

Beep

x 1

 = MEDIUM

Beep

x 2

 = HIGH

Beep

x 3

Beep

Содержание Automate FT

Страница 1: ...N Impact detection senses an obstacle in the blinds path and redirects the blind to protect the motor hardware and fabric ensuring product longevity An intermediate setting allows for a customised fav...

Страница 2: ...P2 function How to activate setting mode p5 3 3 Overview of operational modes p5 3 4 Pairing motor to transmitter p6 3 5 Setting top bottom limits p7 3 6 Set Favourite position p8 3 7 Impact Detection...

Страница 3: ...e drive adaptor should be evenly fixed with 4 pieces of 4x10 countersunk self tapping screws Ensure screw tip does not penetrate through the internal surface of the drive Motor is to be installed in h...

Страница 4: ...e it cools down Isolate power prior to unplugging connector performing maintenance or window cleaning Avoid operation if frost or ice has formed on motorized unit Power off 1 2 3 AC 1 2 3 3 0 75mm 240...

Страница 5: ...ro CH Press P2 RF400s RF500s Below is an overview of how to activate the P2 function on your chosen primary controller 3 3 OVERVIEW OF OPERATIONAL MODES 3 SELECTABLE MODES TENSION Top limit Bottom lim...

Страница 6: ...REQUIRED P2 P2 within 4 seconds within 4 seconds Jog Jog 1 1 Cutting power before limit setting process is complete will result in loss of pairing To reset motor P2 STOP P2 Removes all emitters delet...

Страница 7: ...t Enter step mode 1 1 P2 Jog Jog Jog DOWN UP STOP STOP 1 If pairing multiple motors to a single channel ensure power is switched off prior to proceeding to the next motor Cycle blind up and down first...

Страница 8: ...ion STOP STOP P2 Jog 1 SETTING FAVORITE POSITION DELETING FAVORITE POSITION g ged when the motor stop working or work on the motor head the charging time is se charging the motor battery firstly didn...

Страница 9: ...CHANNEL FROM AN EXISTING PRIMARY TRANSMITTER P2 P2 ON PRIMARY TRANSMITTER 1 Jog ON NEW TRANSMITTER P2 On primary secondary multi channel remotes ensure desired channel is active first 3 7 IMPACT DETE...

Страница 10: ...ETWEEN AUTO MANUAL LOCK MODE TENSION MODE ON TENSION MODE OFF Beep Beep x 1 x 2 P2 STOP DOWN AUTO LOCK MANUAL LOCK Beep x 2 x 5 P2 UP UP Fabric Tension Mode must be ON to switch between Auto Manual Lo...

Страница 11: ...oltage too low 2 Errors in line connection 3 Overload 4 Installation error 5 Transmitter batteries are Flat 1 Check voltage is within the rating specified 2 Check the wiring 3 Verify motor capacity to...

Страница 12: ...6090 T 61 8 9248 5571 F 61 8 9248 5572 ROLLEASE ACMEDA USA 200 Harvard Avenue Stamford CT 06902 6320 T 1 203 964 1573 F 1 203 964 0513 ROLLEASE ACMEDA EUROPE Via Conca Del Naviglio 18 Milan Lombardia...

Отзывы: