Periodical Cleaning Maintenance
77
Chapter 3 Maintenance
Chapter 3 Maintenance
CAUTION
Always carefully follow the procedures in accordance with the instruc-
tions.Otherwise a sudden movement of the machine may cause injury.
Procedure
Open the Utility window.
P.8, "How to Open the Utility Window / Exit the Utility"
In the [Adjustment] tab, click [Manual Head
Cleaning].
Manual Head Cleaning procedures are displayed. Carefully
read the on-screen instructions and start the cleaning tasks.
Carry out test printing and check the result.
Use the cleaning functions and perform cleaning several times if needed.
P.22, "STEP 3: Printing Tests and Normal Cleaning"
requirements for Manual Head Cleaning
Remove media before cleaning.
To prevent the heads from drying out, complete the cleaning within 30 minutes. After 30 minutes a
warning alarm will sound.
Only use the included cleaning sticks. Any other tool, e.g. cotton bud or similar is not designed for this
task and will become fluffy and damage the heads. Please order cleaning sticks directly from us or your
authorized Roland DG Corp. dealer.
Do not use a cleaning stick more than once; the print quality will deteriorate. Dispose of the stick after
each cleaning.
Do not soak a used cleaning stick in cleaning fluid; the cleaning fluid will deteriorate.
Do not rub the nozzle surface of the head.
Clean the sponge section by stroking very lightly and gently. Do not rub, scrape, or flatten the section.
When a warning alarm sounds during cleaning
An alarm sounds 30 minutes after the start of the operation. Perform the operation by following the mes-
sage displayed in the Utility window.
Содержание VersaStudio BR-20
Страница 1: ...MASTER GUIDE ...
Страница 86: ...84 ...
Страница 108: ...106 ...
Страница 109: ...107 ...
Страница 110: ...108 ...
Страница 111: ......
Страница 112: ...R3 120203 ...