background image

14

About the USB Driver

Windows Operating Requirements

Supported Operating Systems

Microsoft® Windows® 7 / 8 / 8.1 / 10 (64-bit / 32-bit)

*  The driver does not work on Windows RT.

Supported Computers

A Windows compatible computer equipped with a USB port

*  We recommend a chipset made by Intel.
*  Intel Core2 processor 1.6 GHz or faster, RAM 1.0 GB or more
*  Performance might be unsatisfactory if this unit is used with a 

USB 2.0 interface card.

*  This unit cannot be used with a USB 3.0 port that is not 

compatible with USB 2.0.

*  If the unit does not operate correctly when connected to a USB 

3.0 port, you’ll need to connect it to a USB 2.0 port.

*  Even if the unit is connected to a USB 3.0 port, the performance 

of the unit itself will not change.

*  This unit cannot be used in a virtual Windows environment such 

as VMware or VirtualBox.

*  Mac computers running Windows are not supported.

Limitations and Cautions

 

5

Depending on the performance and design specifications of 

the computer you’re using, and on the applications you’re using 

and how you’re using them, clicks and pops might occur in the 

sound.

 

5

If you start your computer with a powered-on Rubix already 

connected to the computer, the driver might not be loaded 

correctly, making it impossible to use the Rubix. If this occurs, try 

the following.

 

5

Reconnect the Rubix to a different USB port

 

5

Power-on the Rubix after the computer has started

 

5

Disconnect and reconnect the USB cable

 

5

Sometimes the Rubix might not operate correctly after returning 

from a sleep state. If this occurs, try the following.

 

5

Exit all the applications you’re using, and power-cycle the 

Rubix

 

5

Disconnect and reconnect the USB cable

 

5

If you disconnect and reconnect the USB cable while using 

the Rubix, or power-cycle the Rubix, it might stop operating 

correctly. If this occurs, try the following.

 

5

Exit all the applications you’re using, and power-cycle the 

Rubix

 

5

Disconnect and reconnect the USB cable

 

5

If a high processing load occurs while using the Rubix, such as 

accessing a CD-ROM drive or the network, it might not operate 

correctly. If this occurs, try the following.

 

5

Stop playback/recording, and then resume playback/

recording

 

5

Exit all the applications you’re using, and power-cycle the 

Rubix

 

5

Disconnect and reconnect the USB cable

 

5

If you connect or disconnect another USB device (such as a USB 

flash drive) while using the Rubix, or turn the power of another 

USB device on or off, clicks or pops might occur during playback 

or recording.

 

5

In some cases, performance might be unsatisfactory if the Rubix 

is used simultaneously with a USB-connected hard disk. Don’t 

use a USB-connected hard disk as the save-destination for 

playback or recording.

Mac OS Operating Requirements

Supported Operating Systems

OS X v10.12 / v10.11 / v10.10

*  Check the operating requirements of your audio/MIDI 

application as well as the operating requirements for your 

operating system.

Supported Computers

Apple Mac series computer equipped with a USB port

*  Even if the unit is connected to a USB 3.0 port, the performance 

of the unit itself will not change.

*  Mac computers running Windows are not supported.

Limitations and Cautions

 

5

Connect the Rubix to your computer with a USB cable before 

starting your sequencer software, etc.

 

5

Don’t power-off the Rubix or disconnect the USB cable during 

playback/recording. Doing so might cause the software or 

operating system to shut down abnormally.

 

5

Exit your sequencer software etc. before you power-off the 

Rubix or disconnect the USB cable.

 

5

Before updating the operating system software, disconnect the 

USB cable from the Rubix.

 

5

If the Rubix does not operate correctly after returning from sleep 

or after restarting the operating system, try the following.

 

5

Exit all the applications you’re using, and power-cycle the 

Rubix

 

5

Disconnect and reconnect the USB cable

iPad Operating Requirements

Supported Operating Systems

iOS 9.0 or later

Limitations and Cautions

 

5

Connect the Rubix to your iPad with a USB cable before starting 

your sequencer software, etc.

 

5

Don’t power-off the Rubix or disconnect the USB cable during 

playback/recording. Doing so might cause the software or 

operating system to shut down abnormally.

 

5

Exit your sequencer software etc. before you power-off the 

Rubix or disconnect the USB cable.

 

5

Before updating the iOS software, disconnect the USB cable 

from the Rubix.

 

5

If the Rubix does not operate correctly after restarting iOS, try 

the following.

 

5

Exit all the applications you’re using, and power-cycle the 

Rubix

 

5

Disconnect and reconnect the USB cable

Содержание rubix 22

Страница 1: ...ReferenceManual 2017 Roland Corporation 01...

Страница 2: ...4 Hi Z button Determines the impedance of the INPUT 1L jack You can select high impedance Hi Z or low impedance Lo Z as appropriate for the connected equipment Hi Z button Equipment connected to the I...

Страница 3: ...ard or MIDI controller 5 DIRECT MONITOR switch Determines whether the audio signals input via the INPUT 1L 2R are output directly Switch position Explanation MONO Monitor in mono STEREO Monitor in ste...

Страница 4: ...audio device that is connected 5 5 Use a microphone with an XLR connector The sound level will be very low if you use a microphone with a phone type plug 5 5 When connecting a guitar or bass use the...

Страница 5: ...u might hear noise when turning this knob but this is not a malfunction 10 MONO button If this is turned on the audio signal that is input to the INPUT 1L 2R jacks is monitored in mono MEMO 5 5 When a...

Страница 6: ...T TIP COLD RING 5 5 The wiring of this device uses impedance balancing The audio signal is conveyed via HOT and GND in unbalanced form but since COLD and GND are connected by a resistor the electrical...

Страница 7: ...The sound level will be very low if you use a microphone with a phone type plug 5 5 Whenconnectingaguitarorbass usetheINPUT1L or INPUT 3L jack The sound level will be very low if you connect directly...

Страница 8: ...e connection with a USB device Power indicator Status Lit Connected to a computer or iPad Unlit Not connected to a computer or iPad Rapid blinking The power will soon be turned off automatically by th...

Страница 9: ...c Connect the MIDI IN connector to a MIDI keyboard or MIDI controller 6 9 10 7 8 6 OUTPUT 1L 2R 3L 4R jacks balancedTRS type Output the analog audio signal MEMO 5 5 Pin assignment of OUTPUT jack GND S...

Страница 10: ...ect it before you proceed Installing the USB Driver Before Using the Product for the FirstTime 1 With the Rubix22 Rubix24 Rubix44 not connected start up your computer 2 Download the USB driver from th...

Страница 11: ...the AC adaptor so the side with the indicator see illustration faces upwards and the side with textual information faces downwards The indicator will light when you plug the AC adaptor into an AC out...

Страница 12: ...th the indicator see illustration faces upwards and the side with textual information faces downwards The indicator will light when you plug the AC adaptor into an AC outlet Uninstalling the Driver Wi...

Страница 13: ...13 Getting Ready to Use the Rubix 6 Follow the directions in the screen to uninstall the USB driver If any other message appears proceed as directed by the message...

Страница 14: ...applications you re using and power cycle the Rubix 5 5 Disconnect and reconnect the USB cable 5 5 If you connect or disconnect another USB device such as a USB flash drive while using the Rubix or tu...

Страница 15: ...click the Set as default button 3 Click the OK button Mac OS 1 Open System Preferences and click the Sound icon 2 Click the Output tab and select Rubix22 3 3 Select the model of Rubix that you re usin...

Страница 16: ...data to be transferred smoothly without dropouts You can use the USB buffer setting to change the size of the audio buffer Increasing the size makes data transfer more stable but has the disadvantage...

Страница 17: ...st appropriate setting Select the setting with the shortest delay that still allows stable audio playback Setting Stability Latency 1 Low Short fast 7 High Long slow MEMO Refer to How audio buffer siz...

Страница 18: ...om the INPUT jacks can be sent to your DAW software and recorded To prevent malfunction and equipment failure always turn down the volume and turn off all the units before making any connections Guita...

Страница 19: ...TYPE switch Explanation Response COMP1 When the input signal exceeds the level specified by the THRS knob the level is restrained at a fixed proportion This setting is suitable for instruments such as...

Страница 20: ...does not resolve the issue reinstall the USB driver p 10 Is the Rubix s device name displayed Exit all software that s using the Rubix and then try the following 5 5 Reconnect the USB cable 5 5 Power...

Страница 21: ...ts communications activity to Do nothing 3 Click the OK button to close the Sound window My guitar is too quiet Are you using the correct jack Connect your guitar to the INPUT 1L or INPUT 3L jack p 2...

Страница 22: ...you don t see the High Performance plan click Show Additional Plans 3 In high performance click Change Plan Settings 4 Click Change Detailed Power Settings 5 In detailed settings click for Hard Disk a...

Страница 23: ...and the output of the MIDI sound module be connected to the INPUT 1L or INPUT 2R jack of the Rubix Connect the MIDI sound module and the Rubix to a USB hub that connects to a power supply Have you co...

Страница 24: ...Windows detects communications activity to Do nothing 3 Click the OK button to close the Sound window Windows Is the size of the USB driver s audio buffer too small Increase the size of the USB driver...

Страница 25: ...ppear 5 Click the added new external device icon and then click the Show Info icon 6 Enter Rubix in the Device Name field and then click the Apply button 7 Using your mouse drag and connect the I H bu...

Страница 26: ...I IN OUT Hi SPEED USB DIRECT MONITOR MONO STEREO MIDI IN D A D A PHONES SELECT PHONES OUTPUT OUTPUT 1L OUTPUT 2R OUTPUT 3L OUTPUT 4R PHONES MIDI OUT NOR LIFT NOR LIFT BLOCK DIAGRAM INPUT 1L INPUT 2R 4...

Страница 27: ...1L 2R jacks 6 dBu impedance balanced Maximum Output Level OUTPUT 1L 2R jacks 8 dBu impedance balanced PHONES Maximum Output Power 20 mW 20 mW L R 47 ohms load Headroom 14 dB Input Impedance INPUT 1L...

Страница 28: ...2R jacks 1 4 inch TRS phone type 18 dBu Nominal Output Level OUTPUT 1L 2R 3L 4R jacks 6 dBu impedance balanced Maximum Output Level OUTPUT 1L 2R 3L 4R jacks 8 dBu impedance balanced PHONES Maximum Ou...

Страница 29: ...3L 4R connectors XLR type 2 dBu INPUT 1L 2R 3L 4R jacks 1 4 inch TRS phone type 18 dBu Nominal Output Level OUTPUT 1L 2R 3L 4R jacks 6 dBu impedance balanced Maximum Output Level OUTPUT 1L 2R 3L 4R ja...

Страница 30: ...that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two...

Страница 31: ...31 For EU Countries WARNING This product contains chemicals known to cause cancer birth defects and other reproductive harm including lead For C A US Proposition 65...

Отзывы: