9.24.1 Connection schedule SND40 (general)
The following illustration shows the connection schedule of a SND40 with one sensor as well as
with two sensors via a sensor switch box, together with the names of the required cables.
Fig. 63: Connection schedule with 1 sensor and with 2 sensors via sensor switch box
Pos: 102 /Schweissnaht/Kabel/KNS9S @ 0\mod_1127210825812_501.do cx @ 597 @ 2 @ 1
9.25 Sensor cable KNS9S
Usage: Connecting the combo sensors and the leakage flux sensors to the control unit.
The cable has a cable socket at the sensor side, and open end wires with wire-end ferrules at the
control unit side.
Versions of cable:
KNS9S-G:
straight cable socket at sensor
side
KNS9S-W:
angled cable socket at sensor side
Cable socket at sensor side: Harting HAN8
1:
white
+12 V
2:
green
-12 V
3:
Brown
(+blue)*
AGND
4:
yellow
Meas. signal 1
5:
red
Meas. signal 2
6:
grey
+coil
7:
pink
-coil
**
8: blank
shield
Fig. 64: KNS9S-G
Cable diameter: 8.7 mm
Structure:
8 × 0.5 mm
2
, LiYCY
Bending radius: 54 mm: laid fixed, 130 mm: laid flexible
Note
For cables delivered starting Nov. 2014 following applies:
*
A
brown
wire might be connected parallel together with a
blue
wire.
**
Contact Nr. 8 might be connected with the cable shield.
This will
not affect
the proper functionality of the cable, the
sensor or the control unit.