8
6
Detach the slider retainer you attached earlier.
7
Use two screws to attach the cable clamp and secure the
cable in place. Position the cable clamp so that it is be-
tween the white clamp marks.
8
If you're using the optional safety cover, remove the plate
on the left side of the safety cover.
9
Firmly insert the cable of the rotary axis unit into the
"EXT.3" connector on the main unit. Use a screwdriver to
tighten the connector screws. The machine will not operate
if this cable becomes disconnected or loose. Tighten
securely.
10
Store the center of rotation (Y axis) of the rotary axis unit
in memory. For information about how to do this, refer to
"3-3. Setting the Y- and Z-axis Origin Point at the A-
axis Center of Rotation" and see "Y-axis Center
Alignment."
Part 2 Setting Up
(Safety cover)
Plate
Cable
Cable clamp
Clamp mark
Screw
EXT.3 connector