Connecting REAC Devices
16
When Connecting S-2416 Units to One Another
S-2416: Slave
S-2416: Master
NOTE
Change the setting of the [REAC MODE] switch and [MODE] switch while the S-2416 is powered down.
Slave-unit settings
[REAC MODE] switch
Setting
S (Slave)
[MODE] switch
Setting
1
REAC SLAVE MODE
OFF
CLOCK SLAVE
2
REAC BACKUP MODE
OFF
BACKUP
6
AES/EBU OUTPUT
ON
17-24
Audio signals input via INPUT 17 through 24 on the master unit are
output from AES/EBU OUTPUT on the slave unit.
Master-unit settings
[REAC MODE] switch
Setting
M (Master)
[MODE] switch
Setting
2
REAC BACKUP MODE
OFF
BACKUP
6
AES/EBU OUTPUT
ON
17-24
Audio signals input via INPUT 17 through 24 on the slave unit are
output from AES/EBU OUTPUT on the master unit.