background image

Making Settings for the Input Channels

21

Manipulating Two Channels As a Pair 

(Stereo Link)

Using the Stereo Link feature lets you simultaneously manipulate 

two adjacent channels, one odd-numbered and one even (1 and 2, 

3 and 4, 5 and 6, or 7 and 8). 
Use this when you’re inputting a stereo sound source to the S-0808. 

When Stereo Link is on, the gain, pad, and other settings made on 

the odd-numbered channel are automatically copied to the even-

numbered channel.

Switching On Stereo Link

1. 

Turn the [CHANNEL] knob to select one of the channels 

you want to link.

If you want to link channels 7 and 8, choose [07] or [08].

2. 

Hold down the [CLIP CLEAR/ENTER] button and turn the 

[CHANNEL] knob clockwise.

This switches on Stereo Link.

3. 

Release the [CLIP CLEAR/ENTER] button.

When you release the [CLIP CLEAR/ENTER] button, while the stereo 

link is on, two periods (“.”) appear in the channel number shown on 

the numerical display.

(Example) When ch 7 and 8 are linked

Switching Off Stereo Link

NOTE

Switching off Stereo Link does not make the values and other 

settings go back to what they were before Stereo Link was 

switched on. The values made while linked remain in effect.

1. 

Turn the [CHANNEL] knob to select one of the channels 

you want to unlink.

2. 

Hold down the [CLIP CLEAR/ENTER] button and turn the 

[CHANNEL] knob counterclockwise.

This switches off Stereo Link.

3. 

Release the [CLIP CLEAR/ENTER] button.

When you release the [CLIP CLEAR/ENTER] button, while the stereo 

link is off, the two periods that are displayed disappear from the 

numerical display.

MEMO

Even when Stereo Link is on, you can still 48 V phantom 

power on and off independently for individual channels.

Содержание Digital Snake S-2416

Страница 1: ...Before using the S 2416 ensure that its system program is at the most recent version For information on available upgrades for the system program see the Roland website http proav roland com...

Страница 2: ...rrespond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured GREEN AND YELLOW must be connected to the terminal in the plug which is marked...

Страница 3: ...n top of heat generating equipment or are Damp e g baths washrooms on wet floors or are Exposed to steam or smoke or are Subject to salt exposure or are Exposed to rain or are Dusty or sandy or are Su...

Страница 4: ...before moving the unit Before moving the unit disconnect the power plug from the outlet and pull out all cords from external devices Before cleaning the unit disconnect the power plug from the outlet...

Страница 5: ...romptly wipe it away using a soft dry cloth Maintenance For everyday cleaning wipe the unit with a soft dry cloth or one that has been slightly dampened with water To remove stubborn dirt use a cloth...

Страница 6: ...ing AES EBU INPUT with a Cascade Connection 14 When Using Duplex REAC Lines 15 When Using a Split Connection 15 When Connecting S 2416 Units to One Another 16 Connecting Devices 17 Connecting Input De...

Страница 7: ...angles 2 Using the screws 8 removed in step 1 attach the rack mount angles Be sure to use the screws removed from the unit to secure the angles in place Using different screws might cause damage to t...

Страница 8: ...tings of REAC devices must be made correctly Making the wrong settings may result in incorrect audio input and output M The unit functions as a REAC master device S The unit functions as a REAC slave...

Страница 9: ...connect the word clock source device such as a word clock generator here 75 switch Set this switch to ON when the S 2416 is used as a word clock input terminal WORD CLOCK OUT connector This is the wor...

Страница 10: ...is the master of the sync signal ON CLOCK MASTER The S 2416 is the master of the sync signal You set this when syncing to a word clock signal from an external device such as when using AES EBU input...

Страница 11: ...failure 1 Turn on the power to equipment connected to INPUT on the S 2416 2 Turn on the POWER switch on the S 2416 The POWER indicators front and rear light up Rear panel This unit is equipped with a...

Страница 12: ...terminal plate or other such passive type cable extending connector problems can occur even when length is less than 100 meters Keep the total cable length of the entire chain as short as possible Do...

Страница 13: ...the S 2416 you can make a cascade connection using the REAC BACKUP port This section gives an overview of the settings when connecting the V Mixer with a cascade connection to an S 1608 unit V Mixer M...

Страница 14: ...ASCADE OUTPUT Set according to the application 4 5 AES EBU INPUT OFF ENABLE 7 SAMPLE RATE ON WORD CLOCK 8 ON NOTE Change the setting of the REAC MODE switch and MODE switch while the S 2416 is powered...

Страница 15: ...ection V Mixer Master S 2416 Split S 2416 Slave S 4000D S 2416 settings REAC MODE switch Setting SP Split NOTE Change the setting of the REAC MODE switch while the S 2416 is powered down When a split...

Страница 16: ...tch Setting 1 REAC SLAVE MODE OFF CLOCK SLAVE 2 REAC BACKUP MODE OFF BACKUP 6 AES EBU OUTPUT ON 17 24 Audio signals input via INPUT 17 through 24 on the master unit are output from AES EBU OUTPUT on t...

Страница 17: ...gh 24 When a condenser microphone or the like is connected and supplying phantom power is required switch it on by remote control Refer to Making Settings for the Input Channels p 19 Preamp gain and p...

Страница 18: ...EBU Commercial CD player Digital recorder Speaker processor OUTPUT INPUT OUTPUT OUTPUT Word clock generator IN IN IN IN AES EBU INPUT Settings NOTE The S 2416 has no built in sampling rate converter...

Страница 19: ...S 4000RCS to control the S 2416 is not possible In such cases make the settings using the V Mixer Adjusting the Preamp Gain You can adjust the preamp gain on the S 2416 before sending the signal to a...

Страница 20: ...Phantom Power You can supply phantom power from the S 2416 when a condenser microphone or other device requiring 48 V of power is connected NOTE Be sure to switch off phantom power when no device req...

Страница 21: ...se the CLIP CLEAR ENTER button When you release the CLIP CLEAR ENTER button while the stereo link is on two periods appear in the channel number shown on the numerical display Example When ch 7 and 8...

Страница 22: ...from the following Roland website http proav roland com Refer to the User Guide of S 4000RCS for details of operations and system requirements ConnectingaComputertotheREMOTEConnector Make the connecti...

Страница 23: ...ntain a resistor The gain has not been set correctly Adjust the preamp gain for the channels p 19 p 22 No sound is input via AES EBU INPUT The unit is not synced to the word clock signal from an exter...

Страница 24: ...Equivalent Input Noise Level E I N INPUT jacks 1 24 128 dB Input Gain 65 dBu IHF A typ Network Latency 375 s when using REAC cable only AD to REAC to DA Latency about 1 2 ms 1 Connectors INPUT jacks 1...

Страница 25: ...ata Out 3 RxD Data In 4 NC 5 GND 6 5V 7 Short to pin 8 8 Short to pin 7 9 NC Included RS 232C cable Pins INPUT OUTPUT connector XLR balanced XLR unbalanced Connect COLD and GND when connecting XLR unb...

Страница 26: ...Appendix 26 Dimensions 465 7 177 482 101 6 337 2 430 328 2 UNIT mm...

Страница 27: ...e receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this...

Страница 28: ...For EU Countries For China 5 1 0 0 0 3 9 4 1 3 0 3...

Отзывы: