25
Dwell
G04
Format
G04[X
time(X)
]
G04[P
time(P)
]
Description
G04 specifies the time interval for moving from the previous block to the next block. G04 is normally specified as a single block all by
itself.
G04 is used with the aim of cutting a precise angle, ensuring precision when cutting the bottom of a drilled hole, or the like.
The desired dwell time is specified after X or P. X and P are functionally equivalent, and may be used interchangeably. A numerical
value (real or integer) is used to specify the dwell time. The specified time is in seconds when a real number is used, and in milliseconds
when an integer is used.
G04X10.0
10-second dwell
G04X10000
10-second dwell (in millisecond units)
Parameter
Function
Acceptable range
Effective range
time(X)
Dwell time
Range 1
-
time(P)
Dwell time
Range 2
-