ROLA-CHEM Digital Controller PN 554135 5/04/2017 Page: 20 of 20
8.4 Typical System Installations, cont.,
(REFER TO SPECIFIC INSTRUCTION FROM CHLORINE GENERATOR SUPPLIER)
**OPTIONAL SAFETY FLOWSWITCH TO
ENSURE CIRCULATION TO CONTROL
PROBES AND INDICATOR THAT POOL
CIRCULATION IS OCCURRING.
*SAFETY FLOWSWITCH FOR
PROTECTION OF EQUIPMENT.
*** OPTIONAL STRAINER
AND VALVE TO HELP KEEP
MANIFOLD AND PROBES
CLEAR OF DEBRIS.
SYSTEM USING ELECTROLYTIC CHLORINE GENERATOR
CHLORINE
GENERATOR
CONTROLS
HEATER
EARTH
GROUND
ELECTRICAL OUTLET
CONTROLLED BY
CIRCULATION SYSTEM
WATER
FROM
POOL
BASKET
POOL
PUMP
FILTER
CONTROLLER
*FLOWSWITCH
CELL
WATER
TO POOL
SPDT
120 VAC COIL
RELAY
COM
NO
NC
MANIFOLD
** FLOWSWITCH
***STRAINER
VALVE
**SAFETY FLOWSWITCH TO ENSURE
CIRCULATION TO CONTROL PROBES
AND INDICATOR THAT POOL
CIRCULATION IS OCCURRING.
*SAFETY FLOWSWITCH FOR
PROTECTION OF HEATER AND
TO ENSURE DILUTION OF
CHEMICAL INTO POOL.
*** OPTIONAL STRAINER
AND VALVE TO HELP KEEP
MANIFOLD AND PROBES
CLEAR OF DEBRIS.
STRAINER
SOL. VALVE
(120 VAC)
SYSTEM USING EROSION FEEDER WITH ACID PUMP
(CALCIUM HYPOCHLORITE & MURIATIC ACID)
WATER
FROM
POOL
EARTH
GROUND
POOL
PUMP
FILTER
***STRAINER
MANIFOLD
**FLOWSWITCH
CONTROLLER
EROSION
FEEDER
*FLOWSWITCH
WATER
TO
POOL
EARTH
GROUND
CHECK
VALVE
HEATER
ACID
ACID PUMP
ELECTRICAL
OUTLET
CONTROLLED BY
CIRCULATION
SYSTEM
VALVE