ROLA-CHEM Digital Controller PN 554135 5/04/2017 Page: 6 of 20
Note:
When automating any body of water, it is essential to size the feeders to reach desired
levels in a relatively short period of time. Generally, automating an existing body of water with
existing feeders will require the output of the feeders be increased accordingly. If feeders are
unable to keep up with demand in a short period of time, automation becomes ineffective.
3.2 Specifications
ORP & pH Ranges ORP
pH .
Display:
0 to 995 mV.
6.0 to 8.4
Control:
400 mV to 900 mV 7.0 to 8.0
(5 mV increments)
Factory default:
650 mV
7.4
Input Power:
120 Volts AC, 50/60 HZ, 3 wire grounded power cord
Combined load not to exceed 10 amps
GFCI source required
Output Power:
120 Volts AC, 50/60 HZ, 5 amps (fused) for both ORP and pH
Two 3-wire grounded power receptacles
Terminal strip for hardwire applications included
Displays:
ORP and pH - red digital
Power and flow indicator - LED
Alert indicator & Feed indicator - LED (ORP & pH)
Mode indicator - LED (pH, ORP, Auto)
Note: feed lamps flash during the feed time and are on continuously during the delay time
of the feed cycle.
O
perating
Temperature
:
40 to 120° F
Selectable Features
+ ORP and pH settings
+ Manual feed
+ ORP and pH feed/delay times
+ Keypad lockout
+ pH calibration
+ High and low ORP and pH alerts + Reset
+ ORP and pH Interlock
+ Acid/base feed
+ Adjustable Consecutive Feed Alert Limit
Features and Options
+ Flow switch input
+ Individually fused outputs + 120 VAC transformer