Note: 

When automating any body of water, it is essential to size the feeders to reach desired 

levels in a relatively short period of time. Generally, automating an existing body of water with 
existing feeders will require the output of the feeders be increased accordingly. If feeders are 
unable to keep up with demand in a short period of time, automation becomes ineffective.

 

 
 

3.2 Specifications 

 

ORP & pH Ranges         ORP 

             pH       .     

Display: 

    0 to 995 mV. 

        6.0 to 8.4  

Control: 

 400 mV to 900 mV       7.0 to 8.0 

 

   (5 mV increments) 

Factory default: 

        650 mV  

               7.4 

 

Input Power:  
            120 Volts AC, 50/60 HZ, 3 wire grounded power cord   
  

      Combined load not to exceed 10 amps  

            GFCI source required 
 
Output Power: 

  120 Volts AC, 50/60 HZ, 5 amps (fused) for both ORP and pH 

 

  Two 3-wire grounded power receptacles 

  Terminal strip for hardwire applications included 

 
Displays: 

  ORP and pH - red digital 
  Power and flow indicator - LED 
  Alert indicator & Feed indicator - LED (ORP & pH) 
  Mode indicator - LED (pH, ORP, Auto) 

             
Note: feed lamps flash during the feed time and are on continuously during the delay time 
of the feed cycle. 
                      

 

 

O

perating

 

Temperature

40 to 120° F

      

  
Selectable Features 

+ ORP and pH settings   

 

 

 

 

 

 + Manual feed 

+ ORP and pH feed/delay times 

    + Keypad lockout 

 + pH calibration 

+ High and low ORP and pH alerts     + Reset   

           + ORP and pH Interlock  

+ Acid/base feed 

 

 

    + Adjustable Consecutive Feed Alert Limit 

     

                  

Features and Options 

+ Flow switch input 

+ Individually fused outputs               + 120 VAC transformer   

 

 

 

 

Содержание RC554000

Страница 1: ...F MODE FEED ONCE pH AUTO ORP LEVEL SET pH FEED ALERT CALIB pH FEED TIME HI ORP LOW ORP FEED L O W ALERT pH Operating Manual MODELS RC554XP AND 554000 ORP pH Digital Controller IMPORTANT SAFETY INSTRUC...

Страница 2: ...lso remove power from the controller Provide a properly located outlet controlled by the circulating pump circuit 1 6 WARNING Risk of electric shock pinching chemical exposure Remove power sources or...

Страница 3: ...ols 7 4 Installation 4 1 Locating the controller 10 4 2 Mechanical installation 10 4 3 Power panel access 11 4 3 1 Dip switches 11 4 3 2 Fuses 11 4 3 3 Flow switch 11 5 Operation 5 1 Startup 12 5 2 pH...

Страница 4: ...low pH 8 0 high 7 0 low To Change Settings Press and release the MODE button until the desired ORP or pH LED is lit Once the settings are changed they will remain at those settings until they are chan...

Страница 5: ...ontinuously during the feed delay portion of the feed cycle The ORP Alert lamp will illuminate when the ORP reading is higher or lower than the high and low ORP Alert set points and prevent the feedin...

Страница 6: ...ire grounded power cord Combined load not to exceed 10 amps GFCI source required Output Power 120 Volts AC 50 60 HZ 5 amps fused for both ORP and pH Two 3 wire grounded power receptacles Terminal stri...

Страница 7: ...ing feed delay 4 pH ORP DIGITAL DISPLAYS Monitors pH and ORP and displays programmed set points 5 pH STANDBY LAMP AND PROGRAMMING BUTTONS When pH standby lamp is illuminated the six set buttons are en...

Страница 8: ...ssing the FEED ONCE button the pH feeder will feed and delay for one complete feed cycle See FEED TIME Button for feed delay times If the Feed time is set for Continuous feed the manual feed will not...

Страница 9: ...ET LEVEL button which displays in 5 mV increments until the desired level is reached Feed Time The feed times are displayed in seconds There is a five 5 minute delay time associated with each feed tim...

Страница 10: ...roller in a location accessible to the public Install the controller in an area protected from natural elements sun rain freezing etc See appendix for typical feed system schematics 4 2 Mechanical Ins...

Страница 11: ...dix for settings 4 3 2 Fuses The ORP and pH are independently fused to protect the controller from defective feeders These fuses are located inside the lower panel The fuse holders are shipped with 5...

Страница 12: ...n the OFF mode turn the filter pump on and check for leaks in the system and flow through the flow cell The flow lamp will be illuminated if the controller has power it is connected to the flow switch...

Страница 13: ...until the AUTO LED is lighted This is the operational mode for the controller The controller must be in this mode for the feeders to maintain the desired parameters Note When using the RC554XP or 5540...

Страница 14: ...affected by pH probe Both probes must be in good operating condition 6 3 Set points not being reached maintained Factory setting for feed time is 0 6 sec on with 5 minute delay Feeders may require lo...

Страница 15: ...and return to operating mode The last two steps are extremely important because this puts the controller back in operating mode If these two steps are not performed the controller will remain in test...

Страница 16: ...are not covered under this warranty Heavy duty probes are warranted from the date of original purchase for one 1 year ROLA CHEM under no circumstances shall be liable for any consequential damages di...

Страница 17: ...eed Alert Limit feature in the timed feed mode 1 Turn off remove power then move 2 dip switch to ON 2 Re power press MODE to set it for ORP or pH 3 Set FEED TIME to OFF 4 Press FEED ONCE to select the...

Страница 18: ...mode shortens minutes to seconds E Turn the controller Off again to exit test mode F Turn the controller On to return to operating mode The last two steps are extremely important because this puts th...

Страница 19: ...CLEAR OF DEBRIS FLOWSWITCH EARTH GROUND WATER TO POOL ACID PUMP HEATER ACID HCl MANIFOLD FLOWSWITCH VALVE EARTH GROUND WATER FROM POOL WATER TO POOL EARTH GROUND SYSTEM USING EROSION FEEDER TRI CHLOR...

Страница 20: ...FROM POOL BASKET POOL PUMP FILTER CONTROLLER FLOWSWITCH CELL WATER TO POOL SPDT 120 VAC COIL RELAY COM NO NC MANIFOLD FLOWSWITCH STRAINER VALVE SAFETY FLOWSWITCH TO ENSURE CIRCULATION TO CONTROL PROB...

Отзывы: