 7.   Parts List 

 

550591

550026

550027

550054

550089

550135

550136

PART NO.

2

4

3.3

ITEM NO.

1

pH PROBE- HEAVY DUTY, 8 FT CABLE

FITTING, 1/4 TUBE X 1/4 NPT

TUBING, PE, 1/4 OD x 40 FT

FILTER KIT, 3/8 TUBE  (LARGE FILTER)                 (OPTION)

VALVE, SHUT-OFF, PVC-1/4 TUBE X 1/4 NPT

PROBE FITTING   (qty 2)

ORP PROBE- HEAVY DUTY, 8 FT CABLE

DESCRIPTION

2

1

1

550209

FLOW SWITCH

550183

3.2

FLOWCELL ASSEMBLY, 3/8 TUBE (INCLUDES 3.1 THRU 3.6)

550180

3

FLOWCELL, CLEAR GLOBE

550181

3.1

VALVE, SHUT-OFF, PVC-3/8 TUBE X 1/4 NPT   (qty 3 )

7125190

3.4

3.5

550194

TUBING,PE, 3/8 OD x 40 FT

3.6

550193

FITTING,PP, 3/8 TUBE X 1/4 NPT (qty 2)

ITEMS USED ON FLOWCELLS WITH 1/4 TUBING

3.2

3.1

3.3

3.4

550591 FILTER KIT

(NOT TO SCALE)

3.6

4

550592 FILTER KIT

(NOT TO SCALE)

1

550201

ORP PROBE- GOLD TIP, 8 FT CABLE

ORP PROBE- HEAVY DUTY, 3 FT CABLE

550208

2

pH PROBE- HEAVY DUTY, 3 FT CABLE

550592

4

FILTER KIT, 3/8 TUBE  (SMALL FILTER)                 (OPTION)

4

 

 

Содержание GLOBE FLOWCELL

Страница 1: ...ROLA CHEM Flowcell PN 550182 7 11 2019 page 1 of 8 GLOBE FLOWCELL Operating Manual...

Страница 2: ...r from circulating pump must also remove power from the controller Provide a properly located outlet controlled by the circulating pump circuit 1 3 WARNING Use a device such as a flow switch to remove...

Страница 3: ...jar cap Remove the jar cap and grommet from the probe Save for future probe storage Close left and right Flowcell valves and open the center Flowcell valve Remove nuts from probe fittings and slide on...

Страница 4: ...water sampling Drill and tap a 1 4 NPT thread into a straight section of water pipe at both installation points Screw in 1 4 MNPT x TUBE fitting and tighten Note use Teflon tape on pipe threads and D...

Страница 5: ...flushing filter to prevent damage to probes 5 Maintenance 5 1 Cleaning Periodically approx every month remove Probes from Flowcell and clean them using cotton swab or cloth Clean more frequently as re...

Страница 6: ...0 mV Note It may take three to five minutes for Probes to respond to solution If it takes longer you should replace the Probes 6 1 3 Adjust flowrate through Flowcell Incorrect ORP pH reading can occur...

Страница 7: ...IPTION 2 1 1 550209 FLOW SWITCH 550183 3 2 FLOWCELL ASSEMBLY 3 8 TUBE INCLUDES 3 1 THRU 3 6 550180 3 FLOWCELL CLEAR GLOBE 550181 3 1 VALVE SHUT OFF PVC 3 8 TUBE X 1 4 NPT qty 3 7125190 3 4 3 5 550194...

Страница 8: ...duty probes are warranted from the date of original purchase for one 1 year Standard duty probes are warranted from the date of original purchase for 90 days ROLA CHEM under no circumstances shall be...

Отзывы: