ROLA-CHEM
®
Flowcell PN 550182 7/11/2019 page: 2 of 8
Table of Contents
Section title
Page
1.
Safety Instructions
2
2.
Description
2
3.
Installation
2
4.
Use of Flowcell
5
5.
Maintenance
5
6.
Troubleshooting
6
7.
Parts List
7
8.
Warranty and Service
8
1. SAFETY
See controller manual for additional safety instructions.
1.1
WARNING!
Do not shut down circulating and control system immediately after using
pool, spa or hot tub. Systems must operate until water chemistry is stable. Systems must
be restarted before water chemistry is out of NSPI recommended ranges or water
chemistry must be manually corrected.
1.2
WARNING!
Removing power from circulating pump must also remove power from the
controller. Provide a properly located outlet controlled by the circulating pump circuit.
1.3
WARNING!
Use a device such as a flow switch to remove power from the controller in
the event of pool pump or circulation failure. It is not safe to automatically dispensed
chemicals into a circulating system that is not running.
2. Description
The Flowcell is designed to be used with a controller as part of a chemical automation
system, which continuously monitors and maintains pH balance and sanitizer level in a
swimming pool or spa.
3. Installation
3.1 Mount Flowcell
Pre-mark hole locations for Flowcell mounting screws using the Flowcell. The Flowcell
should not be above the controller unit or other equipment or electrical devices. Flowcell
holes will accept #10 screws.