1.  SAFETY  

 

  

See controller manual for additional safety instructions.  

 

1.1

 

WARNING!

 Do not shut down circulating and control system immediately after using 

pool, spa or hot tub.  Systems must operate until water chemistry is stable. Systems must 
be restarted before water chemistry is out of NSPI recommended ranges or water 
chemistry must be manually corrected. 

 

1.2

 

WARNING!

 Removing power from circulating pump must also remove power from the 

controller. Provide a properly located outlet controlled by the circulating pump circuit. 

 

1.3

 

WARNING!

 Use a device such as a flow switch to remove power from the controller in 

the event of pool pump or circulation failure. It is not safe to automatically dispensed 
chemicals into a circulating system that is not running. 

 

2.  Description  

The Flowcell is designed to be used with a controller as part of a chemical automation 
system, which continuously monitors and maintains pH balance and sanitizer level in a 
swimming pool or spa. 

 

 

3.  Installation 

 

3.1 Mount Flowcell 

Pre-mark hole locations for Flowcell mounting screws using the Flowcell.  The Flowcell 
should not be above the controller unit or other equipment or electrical devices. Flowcell 
holes will accept #10 screws. 

Содержание GLOBE FLOWCELL

Страница 1: ...ROLA CHEM Flowcell PN 550182 7 11 2019 page 1 of 8 GLOBE FLOWCELL Operating Manual...

Страница 2: ...r from circulating pump must also remove power from the controller Provide a properly located outlet controlled by the circulating pump circuit 1 3 WARNING Use a device such as a flow switch to remove...

Страница 3: ...jar cap Remove the jar cap and grommet from the probe Save for future probe storage Close left and right Flowcell valves and open the center Flowcell valve Remove nuts from probe fittings and slide on...

Страница 4: ...water sampling Drill and tap a 1 4 NPT thread into a straight section of water pipe at both installation points Screw in 1 4 MNPT x TUBE fitting and tighten Note use Teflon tape on pipe threads and D...

Страница 5: ...flushing filter to prevent damage to probes 5 Maintenance 5 1 Cleaning Periodically approx every month remove Probes from Flowcell and clean them using cotton swab or cloth Clean more frequently as re...

Страница 6: ...0 mV Note It may take three to five minutes for Probes to respond to solution If it takes longer you should replace the Probes 6 1 3 Adjust flowrate through Flowcell Incorrect ORP pH reading can occur...

Страница 7: ...IPTION 2 1 1 550209 FLOW SWITCH 550183 3 2 FLOWCELL ASSEMBLY 3 8 TUBE INCLUDES 3 1 THRU 3 6 550180 3 FLOWCELL CLEAR GLOBE 550181 3 1 VALVE SHUT OFF PVC 3 8 TUBE X 1 4 NPT qty 3 7125190 3 4 3 5 550194...

Страница 8: ...duty probes are warranted from the date of original purchase for one 1 year Standard duty probes are warranted from the date of original purchase for 90 days ROLA CHEM under no circumstances shall be...

Отзывы: