TROUBLESHOOTING

The VCC does not function independently — it requires

server-installed software to function. Please contact your
software provider before investigating hardware issues.

For Virtual Cash Controller terminal support, please

contact 607-749-2910 or 603-744-2188 between 8:00

a.m. and 6:00 p.m. EST. or e-mail

[email protected]

Initial install

1. Is the network link light lit on the rig ht side of the

terminal? If no, check the cable and connections.

2. Can you ping the VCC unit from the server?

a) Yes – check the server software configuration

b) No

Is the network configured to pass broadcast

packets? Destination port 2613 and source
port 68 must be open for the terminal to

contact the server. TCP ports 1234 and 1235

must also be open.

Will another unit work in that same location?

Will that unit work in another location

closer to the server?

Run the VCC test program on a laptop. You

will need a standard Cat5e Ethernet cable.

Is the hardware in the terminal working?
Check the LED status on the circuit board

when connected to the net work.

3. Does the copier enable when connection is made

with the server software? If not, make sure the

copier harness is correct and that the copier is set to

foreign device or key counter mode. You may use
the copier test function found under the parameters

menu to do this.

4. Does the VCC debit at all? If not, check that the

copier interface is correct with the terminal.

5. Does the VCC debit copies incorrectly? Check the

timing parameters (see page 4).

Post installation

1. Check that the network terminal settings are

correct (you may need to contact the network

administrator locally).

2. Can you ping the VCC from the print software server?

a) Yes. Check all software settings.
b) No. Run the VCC diagnostic tool from your

laptop through the Ethernet port (you will need
a standard Cat5e cable to run the connection

through a hub).

c) Replace the terminal, if the pr oblem persists,

change the local hub and get the network

connectivity verified to your position.

3. The most common fault is caused by the terminal

setting having been changed inadvertently. Ask the

network administrator to keep a record of all

terminal settings for easy reference.

INTERFACING WITH A COPIER

The VCC terminal was designed to be used as a copier

controller and print release station. To function as a

copier controller, the VCC terminal requires an interface
harness specific to the copier an d properly adjusted

interface timing to accurately read the debit pulse.

VCC Copier harness wiring color

Pin Wire color

Function

State

1

Red

Copier input 1

Positive

2

Green

Copier input 1

Negative

3

Yellow/Black

Relay 1

NC

4

White

Relay 1

Common

5

Black

Relay 1

NO

6

Blue

Copier input 2

Positive

7

Orange

Copier input 2

Negative

8

Brown

Relay 2

NC or NO

9

Yellow

Relay 2

Common

10

Grey

Copier input 3

Positive

11

Pink

Copier input 3

Negative

12

Light blue

Copier input 4

Positive

13

Purple

Copier input 4

Negative

14

Red/Black

5 volts

15

Orange/Black

Ground

Interface modes: standard vs. steering

The VCC copier interface port is a high density DB 15;
the pin assignments can be seen in the copier interface

schematic at the end of this guide.

Your VCC terminal can be set to operate in normally
open or normally closed, default is normally open, t o

change to the normally closed setting move jumper JP1

(located near the DB15) to position (2, 3).
The VCC terminal can provide up to 8 price lines

provided the server software gives the relevant

command at boot up. There is no requirement to move

jumpers or even open the enclosure to achieve this.

Содержание VCC

Страница 1: ...rtual Cash Controller product guide page 1 VCC Copy Print controller PRODUCT GUIDE Conforms to FCC CFR 47 part 15 and European Community EMC Directive 89 336 EEC RoHS compliant under EU Directive 2002 95 ...

Страница 2: ...tings Ping utility Card reader test Hostname Network settings Page 7 Static IP DHCP Server Subnet Gateway Domain server DNS MAC broadcast filter Change settings Troubleshooting Page 8 Initial installation Post installation Copier set up Timing parameters Page 9 Leading trailing edge debiting Sense blind time Reset eject delay Firmware upgrade Page 10 Network utility Serial upgrade PCB diagram Page...

Страница 3: ...p for details Keypad The touch screen is fitted with an anti splash membrane to try and prevent accidental spill damage Any liquid caused damage is however not covered by our warranty program Power supply The switching power supply meets worldwide standards and covers universal supplies from 90 to 264 VAC at either 50 Hz or 60 Hz In the event of failure or theft please contact Boscop Inc 1 VCC ter...

Страница 4: ...rietary HID formats we will need the consent of the format owner EM4102 proximity card reader Mostly used in Europe we have fully integrated the 125kHz EM4102 and can supply readers to special order Impro 125kHz proximity card reader We have integrated the Impro Omni Scan reader module this read only device has a scan range of up to 6 It reads Impro Standard Impro Slim and Impro Pico credentials B...

Страница 5: ...er s support staff or help des k before calling Boscop Connection Power cord to wall socket 90 VAC to 264 VAC Ethernet cable not supplied Copier interface harness ordered separately All the connection points are on the rear of the VCC terminal Be sure that the copier interfac e is correctly connected BEFORE powering up the VCC and the copier connecting the copier while power is on may severely dam...

Страница 6: ... on and off by pressing 1 for relay one and pressing 2 for relay two Meters roll over at 10 In steering mode debit pulses should come in only on opto 1 Optos 2 4 provide the steering signal as the copier selections change In this mode Mtrs 1 8 may change Press C CE to exit this selection Test card reader This menu selection provides a way to test the card reader whether it s a mag swipe bar code o...

Страница 7: ...are supported the VCC will only read and save the characters to the left of the first space character To change the settings Static IP mode When the terminal is off line network cable unplugged and the unit is fully booted up swipe your parameters card and select Network settings If you want to manually control your VCC IP pool select Static IP otherwise select DHCP Select Static IP and this will ...

Страница 8: ...rom the print software server a Yes Check all software settings b No Run the VCC diagnostic tool from your laptop through the Ethernet port you will need a standard Cat5e cable to run the connection through a hub c Replace the terminal if the problem persists change the local hub and get the network connectivity verified to your position 3 The most common fault is caused by the terminal setting ha...

Страница 9: ...e after a valid pulse when any further pulses registered by that opto are ignored The valid range is 0 30 seconds in 10ms increments Blind Time masks unwanted pulses i e double pulses or glitches If this parameter is set too short double debits could occur but if set too long vends could be missed The VCC boots with Blind Time set to 10ms Reset Delay This is the length of time that the relays stay...

Страница 10: ...nnect a serial cable between the VCC s DB9 and the PC and activate a serial terminal program such as HyperTerminal Set the communication interface to 57600 8 N 1 and specify hardware flow control The serial cable should be a straight through male to female Apply power to the VCC which will send a menu to HyperTerminal From this menu choose C to flash current firmware location The VCC will then era...

Страница 11: ...oller product guide page 11 VCC PCB LAYOUT In the event that you need to contact our technical support department the following diagram may be helpful There are no components shown on the PCB just the component locations ...

Страница 12: ...ide the warranty period will be subject to our normal rates for parts and labor Shipping costs are your responsibility Please use your shipping account to return your repairs otherwise the return shipping will be at the standard UPS rates All products should be returned to us in their original packaging A charge of 10 will be levied if products are shipped in unsuitable packaging All products rece...

Отзывы: