background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The protective device will work in the following cases. 

  Restarting the unit at once after operation stops or changing mode during   

 

 

   

  operation, you need wait for 3 minutes. 

 

Special  reminder:  there  is  condensing  water  recycling  hidden 

within  this  unit.  The  condensing  water  is  partly  kept  recycling  between  the 
condenser and the water plate. When the water level rises to upper level, the 
float  switch  and  water  full  indicator  (E4)  lights  on  to  remind  draining  water. 
Please  cut  off  the  power  supply,  move  the  appliance  to  a  suitable  place, 
remove  the  drain  plug,  and  connect  the  hose  (inner  diameter  10mm,  not 
included) to drain water completely. After the drain, re-install the drain plug, or 
the appliance may leak and make your room wet. If the appliance is placed in 
a position admitting  drain water,  you  also can  connect the drain hose to the 
drain port to drain water. 

 

 

 

  The protective device may operate and stop the appliance in the cases listed 
below. 

Cooling 

Indoor air temperature is over 43°C 

Room temperature is below 15°C 

Dehumidifying   

Room temperature is below 15°C 

 

 

Содержание R-893

Страница 1: ...R 893 Portable Air Conditioner User s Manual...

Страница 2: ...ree operation 1 All wiring must comply with local and national electrical codes and be installed by a qualified electrician If you have any questions regarding the following instructions contact a qua...

Страница 3: ...be supervised to ensure that they do not place with the appliance 12 Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes throug...

Страница 4: ...Controller 5 Transport Handle 6 Air Outlet Hose 7 Evaporator Air Intake 8 Primary Drain Port The figures in this manual are based on the external view of a standard model Consequently the shape may be...

Страница 5: ...ool Dehumidify Fan 1 Turn on the unit a Plug in then the unit beeps once b Press the button then the unit is turned on The LED displays the room temperature Press the button again the unit is turned o...

Страница 6: ...nd the adjustment of temperature is no effective Cool mode 1 When the room temperature is higher than set temperature the compressor starts to run 2 When the room temperature is lower than set tempera...

Страница 7: ...s and hold the button for 5seconds again the buttons will be unlocked Swing operation When the swing button is activated the swing blade swings left and right automatically If you want to stop press t...

Страница 8: ...tton turn on off the appliance MODE Select the mode SPEED Select the fan speed SETTING Adjust the room temperature and the timer SLEEP MODE Set or cancel Sleep mode operation TIMER Set automatic off a...

Страница 9: ...ns 3 Put on the back cover Notices 1 The anode and cathode of the batteries must be corresponding to the signs of and on the remote control 2 Do not use new battery cells together with run down cells...

Страница 10: ...operate the air conditioner point the remote controller at the signal receptor The remote controller will operate the air conditioner at distance of up to 5m when pointing at signal receptor of the ai...

Страница 11: ...on to remind draining water Please cut off the power supply move the appliance to a suitable place remove the drain plug and connect the hose inner diameter 10mm not included to drain water completely...

Страница 12: ...Pull out the primary and the secondary rubber plug of the drain port to drain the water Re install the rubber plug after drain 2 Keep the appliance running with fan only for a half day during a sunny...

Страница 13: ...batteries in the remote controller are exhausted If the plug is not properly plugged in Runs for a short while only If the set temperature is close to room temperature you can lower the set temperatur...

Страница 14: ...LING mode 1 Room temperature lower than set temperature 2 Machine enters into anti frost protection 1 This is a normal phenomenon the machine will auto switch while the room temperature is higher than...

Страница 15: ...d distance from the return air outlet to the wall or other obstacles at least 60cm 19 1 2 Fix one end of the air hose on the air outlet underside the appliance Extend the air hose to ensure that other...

Страница 16: ...Extend the air exhaust duct A by drawing out the two ends of the duct 2 Screw the air exhaust duct into the connector of air exhaust duct 3 Screw the connector of window into the plastic connectors 4...

Страница 17: ...radios to avoid electromagnetic interference Do not expose the unit under direct sun light to avoid surface color fading Do not tilt the unit for more than 35 or upside down while transporting Place...

Страница 18: ...disposed of as urban waste It must be taken to a special local authority differentiated waste collection centre or to a dealer providing this service Disposing of a household appliance separately avo...