7 | Maintenance
42 / 52
Power Chuck DURO-A
Activity
Interval
Visually inspect wear parts.
Weekly.
Visually inspect jaw screws.
Replace defective screws.
Weekly.
Replace jaw screws.
Annually.
Inspection of the power chuck.
See
.
Annually or at the latest after 500,000
clamping cycles.
7.3
Maintenance Work
7.3.1
Checking the Tightness of Screw Connections
If screws are replaced or undone, incorrect replacement or incorrect attach-
ment may lead to dangers for persons and objects. For this reason, for all
holding screws, the tightening torque recommended by the manufacturer of
the screw must be applied in accordance with the screw grade.
For
cylinder head screws
of the conventional sizes M4 – M24 and strength
classes 8.8, 10.9 and 12.9, the following tightening torque table applies:
Tightening torque in Nm
Strength
class
M3
M4 M5 M6
M8
M10 M12 M14 M16 M18 M20 M22 M24
8.8
1.27 3.0 5.9 10.1 24.6 48
84
133
206
295
415
567 714
10.9
1.79 4.6 8.6 14.9 36.1 71
123
195
302
421
592
807 1,01
7
12.9
2.14 5.1 10 17.4 42.2 83
144
229
354
492
692
945 1,19
0
The table values do
not
apply to tightening torques expressly specified
elsewhere!
When replacing the original screws, the strength class specified by the man-
ufacturer is to be observed. In the case of mounting screws for clamping
devices, clamping inserts, top jaws, rigid stops, pre-clamped covers, equal-
ising weights and comparable elements, strength class 12.9 is always to be
used.