Measurement Principles
R&S
®
RT-ZS60
36
User Manual 1418.7342.02 ─ 01
●
Minimum input impedance |Z
min
|
The resulting input impedance versus frequency is indicated in
. The trace
shows four characteristic areas that can be assigned to R
in
, C
LF
, R
RF
and C
in
. The
resulting loading of a step signal at the input of the probe is given in
.
The connection inductance L
con
has only a minor effect on the signal loading and is
therefore not taken into account in the following.
Fig. 4-8: Magnitude of the input impedance of the R&S
RT-ZS60 probe as a function of fre-
quency
Signal Loading of the Input Signal