Application Examples
R&S
®
OSP
232
User Manual 1178.7100.02 ─ 05
Table 6-2: Brief specifications of preferred relay models
Model
Switch
type
Maximum
frequency
RF connectors
Operating
voltage
Power rating
DPDT
2 GHz
4 × 1 ⅝" EIA (f)
230 V AC
7 kW at 1 GHz
DPDT
5 GHz
4 × 7/16 (f)
24 V DC
2 kW at 1 GHz
DPDT
3.5 GHz
4 × 7/8 EIA (f)
230 V AC
1.5 kW at 1 GHz
Model
BN
512690
C0002 replaces previous model BN
512670, model
BN
640082
replaces previous model BN 640075.
You can use other switches, if they are compatible with the output specifications of the
control lines. Refer to the R&S
OSP datasheet for details.
Make sure to define the delay time by
are connected as shown in
.
Figure 6-5: Connecting diagram for Spinner relays BN... to R&S
OSP-B104
Left
= Overview of basic controls
Right
= Details of the Spinner relay connection plan, with a 9-pin relay port of the R&S
OSP-B104
and some pins of the [IN / OUT] connector
Relay status = Read-in via an optocoupler (isolated, potential-free)
K1/K2
= Two printed relays in the module R&S
OSP-B104, providing isolated potential-free contacts
for controlling a Spinner relay (hence, four times K1/K2)
Applications of Module R&S
OSP-B104