Base Station System ND 951
R&S BICK Mobilfunk GmbH
DVers.: 01 / 28.01.99
951_ENG.DOC
Page: 9 / 14
2.4.3 RX Multicoupler Alarm Number
The adjustments for the receiver multicoupler alarm for the used cassette are set with the
commands F51-F58. These are:
F51/1
F52/1
F53/1
F54/1
F55/2
F56/2
F57/2
F58/2
For the compact system ND951 only the adjustment F51/1 is used.
2.4.4 TX-Antenna VSWR Alarm, Level 1
The TX antenna alarm level 1 for the 4 TX-antennas is adjusted and changed with the commands
F71-F74. The alarm level in relation to the VSWR is eg. set = 1:1,5:
F71/15
F72/15
F73/15
F74/15
2.4.5 TX-Antenna VSWR Alarm, Level 2
The TX antenna alarm level 2 for the 4 TX-antennas is adjusted and changed with the commands
F75-F78. The alarm level in relation to the VSWR is eg. set = 1:2,0:
F75/20
F76/20
F77/20
F78/20
2.4.6 Password
If the CCU is controlled by a modem, a password with the command F91 has to be entered. If the
password is eg. "Deister", this command has to be entered:
F91/Deister