2.4.7 Adjusting the Transceiver
If all transceivers that are connected to the CCU are to be adjusted at the same time, the batch
command of the CCU can be used. The following is put at the beginning of all commands:
B/
If all transceivers that are fitted in a cabinet are to be adjusted at the same time, the batch
command can be used together with the cabinet number:
B1/ ... B2/ .... etc.
If the transceivers of a cabinet are not to be transmitted at the same time, the adjustments are
carried out separately for each transceiver.
2.4.8 Local Block (Separating the Transceivers from the trunked Radio
System)
Before adjusting the transceiver it has to be separated from the trunked radio system.
01+
2.4.9 RX-Configuration
For a standard system without diversity RXA is chosen:
07/A
07/EE++++
2.4.10 TX Power Level
Power level 3 is chosen for a standard system:
13/3
13/EE++++
2.4.11 Delay of the RX Block Alarm
As an example 5 min. are chosen:
76/05
76/EE++++