SCPI Commands HMF series
Remote Control
54
Command Reference
SCPI Programmers Manual
PM:SOURce {INTernal | EXTernal}
Defines the PM modulation source.
Parameters:
<Source>
INTernal | EXTernal
INTernal
:
Internal modulation source.
EXTernal
:
External modulation source.
*RST:
INT
PM:SOURce?
Queries the PM modulation source.
Return values:
INT | EXT
PM:STATe {OFF | ON | 0 | 1}
Activates or deactivates the PM modulation.
Parameters:
<State>
ON | 1
:
The PM modulation will be activated.
OFF | 0
:
The PM modulation will be disabled.
*RST: OFF | 0
PM:STATe?
Queries the state of the PM modulation.
Return values:
ON
:
The PM modulation is activated.
OFF
:
The PM modulation is disabled.