SCPI Commands HMF series
Remote Control
40
Command Reference
SCPI Programmers Manual
VOLTage:OFFSet {<Offset> | MINimum | MAXimum}
Defines the output offset value depending on the amplitude setting.
Parameters:
<Offset>
Numeric value in V (Volt) depending on the amplitude setting.
MIN
:
- 1.01
MAX
: 1.01
*RST:
0.0E+00
VOLTage:OFFSet? [MINimum | MAXimum]
Queries the output offset value.
Return values
:
Numeric value in V (Volt) depending on the amplitude setting.
MIN
:
- 1.01
MAX
: 1.01
FUNCtion:PULSe:WIDTh:HIGH {<Time> | MINimum | MAXimum}
Defines the high width of the pulse function depending on the frequency setting.
Parameters:
<Time>
Numeric value in sec depending on the frequency setting.
MIN
: 2.00E-08
MAX
: 1.05
*RST:
1.00000E-05
FUNCtion:PULSe:WIDTh:HIGH? [MINimum | MAXimum]
Queries the high width of the pulse function depending on the frequency setting.
Return values:
Numeric value in sec depending on the frequency setting.
MIN
: 2.00E-08
MAX
: 1.05
FUNCtion:PULSe:WIDTh:LOW {<Time> | MINimum | MAXimum}
Defines the low width of the pulse function depending on the frequency setting.
Parameters:
<Time>
Numeric value in sec depending on the frequency setting.
MIN
: 2.00E-08
MAX
: 1.05
*RST:
1.00000E-05