Nozzles 

 

Despite being the most important component for accurate uniform spraying application, nozzles are often neglected and 
abused. 
 
Nozzle flow rate depends on effective orifice size and pressure. Spray tip manufacturers have supplied tables of nozzle 
application rates at various pressures, for the best results it is recommended that you  follow these guidelines. 
 
The rule of thumb is that as you increase the pressure to your unit the average droplet size decreases.  Normally with 
conventional open boom sprayers large droplets are used to control drift but large droplets can roll off plants without 
sticking.  With the 

Windfoil

 covered spray system you will be able spray with smaller droplets, increase coverage and 

not worry about drift. 
 
The spray patterns must overlap for even coverage but should not interfere with one another. Nozzles are set at a 10° 
angle so that one edge of its pattern will be just behind the edge of its adjacent spray pattern, evading interference with 
each other. 

 

Typically as a tip wears the spray pattern distorts output volumes usually increase and the droplet characteristics 
change.  Recalibration may correct for output changes, but cannot correct for spray pattern changes or the drop size 
generated. 
 

Caution: 

When spraying next to a flower bed, do not spray over the turf edge as the spray will go 
under the curtain and onto the flowers. 

Diaphragm Check Valve Nozzle Bodies 

Diaphragm check valves close at approximately 15 psi (1 bar) to prevent excessive dripping.  Should the cap on the 
valve loosen or the check valve diaphragm become misaligned, the body may leak.  Stop the leak by, tightening the 
check valve cap or remove the cap and inspect the seal for damage or improper assembly. 
 
To check for defective check valves when the spraying stop control has been actuated, the volume that drips from each 
nozzle should not exceed 2ml timed over a 5 minute period.  The measuring is to start 8 seconds after the flow to the 
spray boom is shut off. 
 
Nozzle caps are attached by engaging the cap and turning clockwise about a third of a turn.  Self-aligning caps have a 
slot to align the tips.  Ensure that the tips fit down into the slotted hole before installing caps on the diaphragm nozzle 
body assembly with the tip screens. 
 
Non-aligning caps are also available for special tips. 
 

Calibration 

As a tip wears recalibration may be required.  Collect the output from each nozzle for 60 seconds, using an accurate 
measuring cup. Use clear water for all testing.  Record the output from each nozzle. Replace nozzles that are more than 
5% above or below the average reading, or has a visibly distorted pattern. 

Содержание WG6

Страница 1: ...06 975 0500 Fax 306 975 0499 Email info rogerssprayers com Web www rogerssprayers com 141 105th Street East Saskatoon SK S7N 1Z2 Canada R o g e r s S p r a y e r s I n c WG6 Windfoil Greensap 6 ft Cov...

Страница 2: ...dies 4 Calibration 4 Application Rate Table 12 spacing 5 GENERAL MAINTENANCE 7 Cleaning 7 Sunshine 8 Winterizing 8 ASSEMBLY 8 Front Wheel Installation 8 Handle attachment 8 Hose attachment 8 Last Chec...

Страница 3: ...t control keep curtain in contact with the ground to ensure a seal to it Drift control of the Windfoil is less effective when the wind blows the curtain off the crop canopy breaking the seal between t...

Страница 4: ...orrect for spray pattern changes or the drop size generated Caution When spraying next to a flower bed do not spray over the turf edge as the spray will go under the curtain and onto the flowers Diaph...

Страница 5: ...2 07 or 40 0 400 79 2 66 0 49 5 39 6 28 3 1 81 1 51 1 13 0 91 0 65 2 76 14061 AXI 8004 50 0 447 88 5 73 8 55 3 44 3 31 6 2 03 1 69 1 27 1 01 0 72 3 45 50 mesh 60 0 490 97 0 80 8 60 6 48 5 34 6 2 22 1...

Страница 6: ...1 95 14061 AXI 8004 50 0 447 88 5 73 8 55 3 44 3 31 6 827 93 689 94 517 45 413 96 295 69 2 18 50 mesh 60 0 490 97 0 80 8 60 6 48 5 34 6 906 95 755 79 566 84 453 47 323 91 2 39 05879 8005VS 30 0 433 8...

Страница 7: ...de some cleaning action in the sprayer Some chemical combinations especially if oil is used may produce a putty type paste buttering out in the sprayer tank and components flushing with water after ea...

Страница 8: ...letely check the sprayer Look at the hoses clamps connections nozzle tips and screens for needed replacements Store the sprayer in a reasonably clean and dry building Assembly There is more than one w...

Страница 9: ...at are plugged or partially plugged Check and clean the appropriate tip s If the balls are right at the top the flow rate is too high for them Replace them with the required balls for the tips see the...

Страница 10: ...Rogers Sprayers Inc Toll Free 1 888 975 8294 www rogerssprayers com 10 WG6 Parts Breakdown...

Страница 11: ...Rogers Sprayers Inc Toll Free 1 888 975 8294 www rogerssprayers com 11 Plumbing Assembly WG FG6...

Страница 12: ...Rogers Sprayers Inc Toll Free 1 888 975 8294 www rogerssprayers com 12 Flowmonitor Assembly...

Страница 13: ...Rogers Sprayers Inc Toll Free 1 888 975 8294 www rogerssprayers com 13 Valve Assembly G Series Part 14530 F111 Tow Hitch...

Страница 14: ...Rogers Sprayers Inc Toll Free 1 888 975 8294 www rogerssprayers com 14...

Страница 15: ...nc Toll Free 1 888 975 8294 www rogerssprayers com 15 Rogers Spra yers Inc 141 105th Street East Saskatoon SK S7N 1Z2 Canada Phone 306 975 0500 Fax 306 975 0499 Email info rogerssprayers com Web www r...

Отзывы: