Many people die or suffer serious injury in job related accidents every year due to carelessness. Know your machinery 
and be aware of potential hazards. Put safety first in all your operations. 
 
Review all instructions and procedures outlined in this manual annually. Every operator must familiarize himself with the 
operating instructions of the sprayer. 

Operational Safety 

 

Shut down sprayer and power unit and wait for all parts to stop before adjusting, cleaning, or lubricating the power unit or 
sprayer. 
 
Before spraying a field familiarize yourself with any rocks, debris, trees, ditches or gullies that may be potentially  
dangerous.  Plan the spraying route to avoid these hazards. 
 
Spray only chemicals that unit was designed for, (ie turf application).  Do not use products for which unit was not  
designed, (ie PAINT, sealants, cleaning fluids, dust inhibitors, ice surfaces). 

Minimize Chemical Drift

 

 
The 

Windfoil

 sprayer was designed in a wind tunnel to control air flow around and behind the sprayer  minimizing drift to 

allow safer spraying in windy conditions. 
 
Drift can blow off a field after it has been sprayed, especially in high winds. Reasonable caution should be taken in order 
to spray effectively and safely. 
 

For maximum drift control, keep curtain in contact with the ground to ensure a seal to it. Drift control of the 

Windfoil

 is less effective when the wind blows the curtain off the crop canopy breaking the seal between the 

curtain and the crop. 

Application Tips 

 

Always use clean filtered water in the sprayer tank. 
 
Your 

Windfoil

 

Drift Containment Spray System (DCSS) comes standard with ceramic insert tips.  These tips are  

considered by most to be the best in the industry for wear resistance and spray pattern coefficient of variation.  Please 
contact your manufacturer for various sizes of tips available for your machine. 
 
Ensure that the pressure on the supply end of the hose used on hose reels is sufficient to deliver the proper pressure at 
the hand unit on the delivery end of the hose. 
 
Check the flow rate from all nozzles using the capacity calibration technique; see the Calibration section for tables and 
instructions. Use clean filtered water for all calibration testing.  Adjust the sprayer pressure to get the proper flow rate. 
The flow meters are not accurate enough in absolute terms to be used as a flow meter. In relative terms they are very 
accurate. 

Safety 

Safety 

General Spraying Information 

Caution:  

Conventional tips are rated at 40 psi (3 bar), for example a 8004 tip at 40 psi (3 bar) delivers 0.4 US 
gal/min (1.5 litres/min) . Only conventional 80° tips are recommended for the 

Windfoil WG 

series.  Wider 

angle tips (110°) have a wider pattern than 80° and will hit the curtain at the ends of the boom and are 

Содержание WG6

Страница 1: ...06 975 0500 Fax 306 975 0499 Email info rogerssprayers com Web www rogerssprayers com 141 105th Street East Saskatoon SK S7N 1Z2 Canada R o g e r s S p r a y e r s I n c WG6 Windfoil Greensap 6 ft Cov...

Страница 2: ...dies 4 Calibration 4 Application Rate Table 12 spacing 5 GENERAL MAINTENANCE 7 Cleaning 7 Sunshine 8 Winterizing 8 ASSEMBLY 8 Front Wheel Installation 8 Handle attachment 8 Hose attachment 8 Last Chec...

Страница 3: ...t control keep curtain in contact with the ground to ensure a seal to it Drift control of the Windfoil is less effective when the wind blows the curtain off the crop canopy breaking the seal between t...

Страница 4: ...orrect for spray pattern changes or the drop size generated Caution When spraying next to a flower bed do not spray over the turf edge as the spray will go under the curtain and onto the flowers Diaph...

Страница 5: ...2 07 or 40 0 400 79 2 66 0 49 5 39 6 28 3 1 81 1 51 1 13 0 91 0 65 2 76 14061 AXI 8004 50 0 447 88 5 73 8 55 3 44 3 31 6 2 03 1 69 1 27 1 01 0 72 3 45 50 mesh 60 0 490 97 0 80 8 60 6 48 5 34 6 2 22 1...

Страница 6: ...1 95 14061 AXI 8004 50 0 447 88 5 73 8 55 3 44 3 31 6 827 93 689 94 517 45 413 96 295 69 2 18 50 mesh 60 0 490 97 0 80 8 60 6 48 5 34 6 906 95 755 79 566 84 453 47 323 91 2 39 05879 8005VS 30 0 433 8...

Страница 7: ...de some cleaning action in the sprayer Some chemical combinations especially if oil is used may produce a putty type paste buttering out in the sprayer tank and components flushing with water after ea...

Страница 8: ...letely check the sprayer Look at the hoses clamps connections nozzle tips and screens for needed replacements Store the sprayer in a reasonably clean and dry building Assembly There is more than one w...

Страница 9: ...at are plugged or partially plugged Check and clean the appropriate tip s If the balls are right at the top the flow rate is too high for them Replace them with the required balls for the tips see the...

Страница 10: ...Rogers Sprayers Inc Toll Free 1 888 975 8294 www rogerssprayers com 10 WG6 Parts Breakdown...

Страница 11: ...Rogers Sprayers Inc Toll Free 1 888 975 8294 www rogerssprayers com 11 Plumbing Assembly WG FG6...

Страница 12: ...Rogers Sprayers Inc Toll Free 1 888 975 8294 www rogerssprayers com 12 Flowmonitor Assembly...

Страница 13: ...Rogers Sprayers Inc Toll Free 1 888 975 8294 www rogerssprayers com 13 Valve Assembly G Series Part 14530 F111 Tow Hitch...

Страница 14: ...Rogers Sprayers Inc Toll Free 1 888 975 8294 www rogerssprayers com 14...

Страница 15: ...nc Toll Free 1 888 975 8294 www rogerssprayers com 15 Rogers Spra yers Inc 141 105th Street East Saskatoon SK S7N 1Z2 Canada Phone 306 975 0500 Fax 306 975 0499 Email info rogerssprayers com Web www r...

Отзывы: