RWL-1-SL Operating Manual.doc
2021-12-20
7/13
LED indicators
RWL-1-SL lock is equipped with 3 LED indicators which functions are described in the table below.
LED indicators
Name
Colour
Description
LED RED
Red
Indicator is blinking when lock waits for the optional second
card reading. If it occurs, lock switches to
Office mode
.
LED BLUE
Blue
Indicator:
·
2 sec pulse when access is granted and external
handle is coupled
·
two 2 sec pulses when access is denied
·
lights steadily when operates in
Office mode
LED
SYSTEM
Orange
·
lights steadily in case of lock’s configuration error
·
pulses slowly in case of low battery level (batteries
must be replaced)
Power supply
RWL-1-SL lock is supplied from 4 pcs of AA batteries. In case of average 10 operations daily the
alkaline batteries enable 2 year functioning. Low battery level is signalled locally by orange LED
SYSTEM pulsing and acoustic signal generated prior to entering standby mode.
C
ONFIGURATION
RWL-1 lock can be programmed manually or from PC computer. All configuration settings can be
setup and edited using RogerVDM program. Connection to PC requires RUD-1 interface.
Factory new lock is configured with 2 programming cards (ADD card and DEL card).
Lock pulse
by
default is set to 2 sec while built-in RFID reader is configured to read card serial numbers (CSN).
Factory cards
Label
Name
Authorization
ADD
ADD programming card
New card adding to the lock
DEL
DEL programming card
Card deleting from the lock
Configuration recovery from the lock
In some circumstances it might be required to recover the configuration settings from the lock. Such
operation can be done by means of RogerVDM software. Regardless of the operating mode it is not
possible to recover communication password and card encryption keys. Recovery of the user cards
programmed in the lock’s memory, can be disabled by means of
Card codes protection
option, which
by default is set off so the card codes can be read from the lock’s memory.
Note: Once the
Card code protection
option is set, the only way to clear it is to execute memory reset
which erases entire lock’s memory.
Manual programming of the users
The lock can be configured manually without computer. Using manual programming it is possible to
add and delete user cards. Factory new lock is configured with
Backup cards
and delivered with 2
programming cards (ADD card and DEL card). The manual programming of the users can be used
either when lock operates with
Backup cards
(50 users limit) or without
Backup cards
(100 users